RP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

RCT Power Energy Technology Power Storage DC US-8.0 PRO (8.032 kW)

8 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.032 kW
CEC Weighted Eff.
97%
MPPT / Max DC
220–420V / 420V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
RCT Power Energy Technology Power Storage DC US-8.0 PRO — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–420 Vdc 220V 420V MAX 420V PV DC INPUT ≤ 420V DC 8.032 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

RCT Power Energy Technology Power Storage DC US-8.0 PRO Electrical and Grid-Support Specifications
ManufacturerRCT Power Energy Technology
Model Number (MPN)Power Storage DC US-8.0 PRO
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.032 kW (8,032 W)
Nominal DC Input (Pdco)8,267 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window220 – 420 Vdc (NREL SAM Measured)
Max DC Input Voltage420 Vdc
Max DC Input Current23 A
Night Tare Loss0.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Power Storage DC US-8.0 PRO
Max Continuous AC Current33.5 A @ 240V
125% Continuous Duty Current41.9 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.84–10.84 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Power Storage DC US-8.0 PRO
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for RCT Power Energy Technology Power Storage DC US-8.0 PRO

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for RCT Power Energy Technology Power Storage DC US-8.0 PRO
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–5 per string (-10°C)Verify Pair

Engineering FAQ — RCT Power Energy Technology Power Storage DC US-8.0 PRO

What size circuit breaker does the RCT Power Energy Technology Power Storage DC US-8.0 PRO require under NEC 705.12?
At 8.032 kW continuous AC output on 240V (33.5A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the RCT Power Energy Technology Power Storage DC US-8.0 PRO?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.032 kW unit with 8.84 kW to 10.84 kW DC of solar modules without exceeding 420V cold Voc.

More RCT Power Energy Technology Inverters

Power Storage DC US-15.0 (14.947 kW)Power Storage DC US-8.0 (8.032 kW)All RCT Power Energy Technology Equipment →