Shenzhen Kstar New Energy Company E15KD (14.993 kW)
15 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
14.993 kW
CEC Weighted Eff.
97%
MPPT / Max DC
240–400V / 400V
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Shenzhen Kstar New Energy Company |
|---|---|
| Model Number (MPN) | E15KD |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 14.993 kW (14,993 W) |
| Nominal DC Input (Pdco) | 15,633 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 240 – 400 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 400 Vdc |
| Max DC Input Current | 52.1 A |
| Night Tare Loss | 20.79 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 62.5 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 78.1 A |
| Minimum Standard Breaker | 80 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (16.49–20.24 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 41–51 panels | 16.4–20.4 kW DC |
| 440W | 37–46 panels | 16.3–20.2 kW DC |
| 550W | 30–37 panels | 16.5–20.4 kW DC |
Compatible Solar Panels for Shenzhen Kstar New Energy Company E15KD
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–7 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–7 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–7 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–7 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 10–10 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | 9–9 per string (-10°C) | Verify Pair |
Engineering FAQ — Shenzhen Kstar New Energy Company E15KD
What size circuit breaker does the Shenzhen Kstar New Energy Company E15KD require under NEC 705.12?
At 14.993 kW continuous AC output on 240V (62.5A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Shenzhen Kstar New Energy Company E15KD?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 14.993 kW unit with 16.49 kW to 20.24 kW DC of solar modules without exceeding 400V cold Voc.