SMA Solar official logoCEC-Listed · 240V ResidentialHybridBattery Hybrid

SMA Solar SBS6.0-US-10 (6 kW)

6.0 kW, 240 Vac, 1-phase, Sunny Boy Storage- Permanently-connected, Transformerless Multimode - Grid Support Utility Interactive and Standalone functionality - Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
220–550V / 550V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SMA Solar SBS6.0-US-10 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–550 Vdc 220V 550V MAX 550V PV DC INPUT ≤ 550V DC 6 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

SMA Solar SBS6.0-US-10 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)SBS6.0-US-10
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6 kW (6,000 W)
Nominal DC Input (Pdco)6,215 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window220 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current17.3 A
Night Tare Loss6.53 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SBS6.0-US-10
Max Continuous AC Current25 A @ 240V
125% Continuous Duty Current31.3 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.6–8.1 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SBS6.0-US-10
Panel ClassRecommended QtyDC Array / Ratio
400W17–20 panels6.8–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for SMA Solar SBS6.0-US-10

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar SBS6.0-US-10
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar SBS6.0-US-10

What size circuit breaker does the SMA Solar SBS6.0-US-10 require under NEC 705.12?
At 6 kW continuous AC output on 240V (25A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SMA Solar SBS6.0-US-10?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6 kW unit with 6.6 kW to 8.1 kW DC of solar modules without exceeding 550V cold Voc.

More SMA Solar Inverters

SBS5.0-US-10 (5 kW)SBSE5.8-US-50 (5.776 kW)SB6.0-1SP-US-40 (6 kW)SB7.0-1SP-US-40 (7 kW)SBSE7.7-US-50 (7.622 kW)SB7.7-1SP-US-40 (7.68 kW)All SMA Solar Equipment →