SMA Solar official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SMA Solar SBSE7.7-US-50 (7.622 kW)

7.7 kW, 240 Vac Grid Support Utility Interactive Inverters. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.622 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
180–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SMA Solar SBSE7.7-US-50 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 180–480 Vdc 180V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.622 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

SMA Solar SBSE7.7-US-50 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)SBSE7.7-US-50
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.622 kW (7,622 W)
Nominal DC Input (Pdco)7,842 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window180 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current19.6 A
Night Tare Loss11.22 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryUL
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SBSE7.7-US-50
Max Continuous AC Current31.8 A @ 240V
125% Continuous Duty Current39.8 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.38–10.29 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SBSE7.7-US-50
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for SMA Solar SBSE7.7-US-50

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar SBSE7.7-US-50
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar SBSE7.7-US-50

What size circuit breaker does the SMA Solar SBSE7.7-US-50 require under NEC 705.12?
At 7.622 kW continuous AC output on 240V (31.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SMA Solar SBSE7.7-US-50?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.622 kW unit with 8.38 kW to 10.29 kW DC of solar modules without exceeding 480V cold Voc.

More SMA Solar Inverters

SB6.0-1SP-US-40 (6 kW)SBS6.0-US-10 (6 kW)SB7.0-1SP-US-40 (7 kW)SB7.7-1SP-US-40 (7.68 kW)SBSE9.6-US-50 (9.569 kW)SBSE11.5-US-50 (11.483 kW)All SMA Solar Equipment →