SolarJuice American S4A-A60 (5.732 kW)
6 kW, 240 Vac, 1-phase, transformerless, bidirectional, battery Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5.732 kW
CEC Weighted Eff.
94%
MPPT / Max DC
360–500V / 500V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | SolarJuice American |
|---|---|
| Model Number (MPN) | S4A-A60 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 5.732 kW (5,732 W) |
| Nominal DC Input (Pdco) | 6,025 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 94% |
| MPPT Operating Window | 360 – 500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 500 Vdc |
| Max DC Input Current | 14 A |
| Night Tare Loss | 25 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 23.9 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 29.9 A |
| Minimum Standard Breaker | 30 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (6.31–7.74 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 16–19 panels | 6.4–7.6 kW DC |
| 440W | 14–18 panels | 6.2–7.9 kW DC |
| 550W | 11–14 panels | 6.0–7.7 kW DC |
Engineering FAQ — SolarJuice American S4A-A60
What size circuit breaker does the SolarJuice American S4A-A60 require under NEC 705.12?
At 5.732 kW continuous AC output on 240V (23.9A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarJuice American S4A-A60?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.732 kW unit with 6.31 kW to 7.74 kW DC of solar modules without exceeding 500V cold Voc.