SolarJuice American S4A-A86 (8.613 kW)
8.6 kW, 240 Vac, 1-phase, transformerless, bidirectional, battery Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
8.613 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
363–430V / 430V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | SolarJuice American |
|---|---|
| Model Number (MPN) | S4A-A86 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 8.613 kW (8,613 W) |
| Nominal DC Input (Pdco) | 9,036 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 95.5% |
| MPPT Operating Window | 363 – 430 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 430 Vdc |
| Max DC Input Current | 22.8 A |
| Night Tare Loss | 42 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 35.9 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 44.9 A |
| Minimum Standard Breaker | 45 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (9.47–11.63 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 24–29 panels | 9.6–11.6 kW DC |
| 440W | 22–26 panels | 9.7–11.4 kW DC |
| 550W | 17–21 panels | 9.3–11.6 kW DC |
Engineering FAQ — SolarJuice American S4A-A86
What size circuit breaker does the SolarJuice American S4A-A86 require under NEC 705.12?
At 8.613 kW continuous AC output on 240V (35.9A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarJuice American S4A-A86?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.613 kW unit with 9.47 kW to 11.63 kW DC of solar modules without exceeding 430V cold Voc.