SL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Solis (Ginlong) S6-EH1P3.8K-H-US (3.801 kW)

3.8 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.801 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
140–450V / 450V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Solis (Ginlong) S6-EH1P3.8K-H-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 140–450 Vdc 140V 450V MAX 450V PV DC INPUT ≤ 450V DC 3.801 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Solis (Ginlong) S6-EH1P3.8K-H-US Electrical and Grid-Support Specifications
ManufacturerSolis (Ginlong)
Model Number (MPN)S6-EH1P3.8K-H-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.801 kW (3,801 W)
Nominal DC Input (Pdco)3,928 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window140 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current10.6 A
Night Tare Loss18.83 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for S6-EH1P3.8K-H-US
Max Continuous AC Current15.8 A @ 240V
125% Continuous Duty Current19.8 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.18–5.13 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for S6-EH1P3.8K-H-US
Panel ClassRecommended QtyDC Array / Ratio
400W10–13 panels4.0–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Compatible Solar Panels for Solis (Ginlong) S6-EH1P3.8K-H-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Solis (Ginlong) S6-EH1P3.8K-H-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–6 per string (-10°C)Verify Pair

Engineering FAQ — Solis (Ginlong) S6-EH1P3.8K-H-US

What size circuit breaker does the Solis (Ginlong) S6-EH1P3.8K-H-US require under NEC 705.12?
At 3.801 kW continuous AC output on 240V (15.8A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Solis (Ginlong) S6-EH1P3.8K-H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.801 kW unit with 4.18 kW to 5.13 kW DC of solar modules without exceeding 450V cold Voc.

More Solis (Ginlong) Inverters

1P2.5K-4G-US (2.5 kW)1P3K-4G-US (3 kW)1P3.6K-4G-US (3.6 kW)1P4K-4G-US (4 kW)1P4.6K-4G-US (4.6 kW)1P5K-4G-US (5 kW)All Solis (Ginlong) Equipment →