SL CEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

Solis (Ginlong) 1P3.6K-4G-US (3.6 kW)

3.6 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.6 kW
CEC Weighted Eff.
97%
MPPT / Max DC
180–500V / 500V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Solis (Ginlong) 1P3.6K-4G-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 180–500 Vdc 180V 500V MAX 500V PV DC INPUT ≤ 500V DC 3.6 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Solis (Ginlong) 1P3.6K-4G-US Electrical and Grid-Support Specifications
ManufacturerSolis (Ginlong)
Model Number (MPN)1P3.6K-4G-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)3.6 kW (3,600 W)
Nominal DC Input (Pdco)3,720 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window180 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current11.3 A
Night Tare Loss3.5 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 1P3.6K-4G-US
Max Continuous AC Current15 A @ 240V
125% Continuous Duty Current18.8 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (3.96–4.86 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 1P3.6K-4G-US
Panel ClassRecommended QtyDC Array / Ratio
400W10–12 panels4.0–4.8 kW DC
440W9–11 panels4.0–4.8 kW DC
550W7–9 panels3.9–5.0 kW DC

Compatible Solar Panels for Solis (Ginlong) 1P3.6K-4G-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Solis (Ginlong) 1P3.6K-4G-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–7 per string (-10°C)Verify Pair

Engineering FAQ — Solis (Ginlong) 1P3.6K-4G-US

What size circuit breaker does the Solis (Ginlong) 1P3.6K-4G-US require under NEC 705.12?
At 3.6 kW continuous AC output on 240V (15A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Solis (Ginlong) 1P3.6K-4G-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.6 kW unit with 3.96 kW to 4.86 kW DC of solar modules without exceeding 500V cold Voc.

More Solis (Ginlong) Inverters

S6-EH2P16K03-SV-YD-L-US-E (15.94 kW)1P2.5K-4G-US (2.5 kW)1P3K-4G-US (3 kW)S6-EH1P3.8K-H-US (3.801 kW)1P4K-4G-US (4 kW)1P4.6K-4G-US (4.6 kW)All Solis (Ginlong) Equipment →