SS CEC-Listed · 240V ResidentialMicroinverter

Sparq Systems Q1200-4101 (1.165 kW)

1200 W, 240 Vac, 60Hz Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.165 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
28–55V / 31V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sparq Systems Q1200-4101 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 28–55 Vdc 28V 55V MAX 31V PV DC INPUT ≤ 31V DC 1.165 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Sparq Systems Q1200-4101 Electrical and Grid-Support Specifications
ManufacturerSparq Systems
Model Number (MPN)Q1200-4101
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.165 kW (1,165 W)
Nominal DC Input (Pdco)1,203 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window28 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage31 Vdc
Max DC Input Current41.5 A
Night Tare Loss0.04 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Q1200-4101
Max Continuous AC Current4.9 A @ 240V
125% Continuous Duty Current6.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.28–1.57 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Q1200-4101
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.34× DC/AC)
440W1 panel1:1 pairing (0.38× DC/AC)
550W1 panel1:1 pairing (0.47× DC/AC)

Engineering FAQ — Sparq Systems Q1200-4101

What size circuit breaker does the Sparq Systems Q1200-4101 require under NEC 705.12?
At 1.165 kW continuous AC output on 240V (4.9A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Sparq Systems Q1200-4101?
As a 1165W microinverter, it pairs 1:1 with panels rated roughly 1223W to 1689W STC.

More Sparq Systems Inverters

Q1200-4102 (1.203 kW)Q2000-4102 (1.72 kW)All Sparq Systems Equipment →