SS CEC-Listed · 240V ResidentialMicroinverter

Sparq Systems Q2000-4102 (1.72 kW)

2000 W, 240 Vac, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.72 kW
CEC Weighted Eff.
97%
MPPT / Max DC
36–38V / 38V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sparq Systems Q2000-4102 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 36–38 Vdc 36V 38V MAX 38V PV DC INPUT ≤ 38V DC 1.72 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Sparq Systems Q2000-4102 Electrical and Grid-Support Specifications
ManufacturerSparq Systems
Model Number (MPN)Q2000-4102
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.72 kW (1,720 W)
Nominal DC Input (Pdco)1,778 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window36 – 38 Vdc (NREL SAM Measured)
Max DC Input Voltage38 Vdc
Max DC Input Current47.4 A
Night Tare LossNot reported in CEC
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Q2000-4102
Max Continuous AC Current7.2 A @ 240V
125% Continuous Duty Current9.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.89–2.32 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Q2000-4102
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.23× DC/AC)
440W1 panel1:1 pairing (0.26× DC/AC)
550W1 panel1:1 pairing (0.32× DC/AC)

Engineering FAQ — Sparq Systems Q2000-4102

What size circuit breaker does the Sparq Systems Q2000-4102 require under NEC 705.12?
At 1.72 kW continuous AC output on 240V (7.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Sparq Systems Q2000-4102?
As a 1720W microinverter, it pairs 1:1 with panels rated roughly 1806W to 2494W STC.

More Sparq Systems Inverters

Q1200-4101 (1.165 kW)Q1200-4102 (1.203 kW)All Sparq Systems Equipment →