SRNE Solar HEBP48120U240-Pro (11.996 kW)
12 kW, 240 Vac, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
11.996 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
275–450V / 450V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | SRNE Solar |
|---|---|
| Model Number (MPN) | HEBP48120U240-Pro |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 11.996 kW (11,996 W) |
| Nominal DC Input (Pdco) | 12,573 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 275 – 450 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 450 Vdc |
| Max DC Input Current | 34.7 A |
| Night Tare Loss | 74.3 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 50 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 62.5 A |
| Minimum Standard Breaker | 70 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (13.2–16.19 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 33–40 panels | 13.2–16.0 kW DC |
| 440W | 30–37 panels | 13.2–16.3 kW DC |
| 550W | 24–29 panels | 13.2–15.9 kW DC |
Compatible Solar Panels for SRNE Solar HEBP48120U240-Pro
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 8–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 8–8 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–6 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 11–11 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | 10–10 per string (-10°C) | Verify Pair |
Engineering FAQ — SRNE Solar HEBP48120U240-Pro
What size circuit breaker does the SRNE Solar HEBP48120U240-Pro require under NEC 705.12?
At 11.996 kW continuous AC output on 240V (50A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SRNE Solar HEBP48120U240-Pro?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.996 kW unit with 13.2 kW to 16.19 kW DC of solar modules without exceeding 450V cold Voc.