SRNE Solar HESP4880U200-H (8.81 kW)
8 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
8.81 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
275–450V / 450V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | SRNE Solar |
|---|---|
| Model Number (MPN) | HESP4880U200-H |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 8.81 kW (8,810 W) |
| Nominal DC Input (Pdco) | 9,185 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 275 – 450 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 450 Vdc |
| Max DC Input Current | 25.3 A |
| Night Tare Loss | 73.1 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 36.7 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 45.9 A |
| Minimum Standard Breaker | 50 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (9.69–11.89 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 24–30 panels | 9.6–12.0 kW DC |
| 440W | 22–27 panels | 9.7–11.9 kW DC |
| 550W | 18–22 panels | 9.9–12.1 kW DC |
Compatible Solar Panels for SRNE Solar HESP4880U200-H
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 8–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 8–8 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–6 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 11–11 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | 10–10 per string (-10°C) | Verify Pair |
Engineering FAQ — SRNE Solar HESP4880U200-H
What size circuit breaker does the SRNE Solar HESP4880U200-H require under NEC 705.12?
At 8.81 kW continuous AC output on 240V (36.7A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SRNE Solar HESP4880U200-H?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.81 kW unit with 9.69 kW to 11.89 kW DC of solar modules without exceeding 450V cold Voc.