SC CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Star Charge Americas SI104LULA00 (9.582 kW)

9.5 kW, 240 Vac, Transformerless Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.582 kW
CEC Weighted Eff.
97%
MPPT / Max DC
320–480V / 480V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Star Charge Americas SI104LULA00 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 320–480 Vdc 320V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.582 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

Star Charge Americas SI104LULA00 Electrical and Grid-Support Specifications
ManufacturerStar Charge Americas
Model Number (MPN)SI104LULA00
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.582 kW (9,582 W)
Nominal DC Input (Pdco)9,914 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window320 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current27.5 A
Night Tare Loss6.26 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SI104LULA00
Max Continuous AC Current39.9 A @ 240V
125% Continuous Duty Current49.9 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.54–12.94 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SI104LULA00
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–24 panels10.4–13.2 kW DC

Compatible Solar Panels for Star Charge Americas SI104LULA00

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Star Charge Americas SI104LULA00
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-560-BTC-HV560 W48.81 V9–9 per string (-10°C)Verify Pair
Silfab Solar SIL-540XM540 W47.95 V9–9 per string (-10°C)Verify Pair
Canadian Solar CS6.2-48TM-430H430 W35 V13–13 per string (-10°C)Verify Pair
REC Solar REC430AA Pure 2430 W49 V9–9 per string (-10°C)Verify Pair

Engineering FAQ — Star Charge Americas SI104LULA00

What size circuit breaker does the Star Charge Americas SI104LULA00 require under NEC 705.12?
At 9.582 kW continuous AC output on 240V (39.9A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Star Charge Americas SI104LULA00?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.582 kW unit with 10.54 kW to 12.94 kW DC of solar modules without exceeding 480V cold Voc.

More Star Charge Americas Inverters

SI403LULA00 (3.811 kW)SI803LULA00 (7.641 kW)All Star Charge Americas Equipment →