SC CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Star Charge Americas SI403LULA00 (3.811 kW)

3.8 kW, 240 Vac, Transformerless Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.811 kW
CEC Weighted Eff.
96%
MPPT / Max DC
180–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Star Charge Americas SI403LULA00 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 180–480 Vdc 180V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.811 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Star Charge Americas SI403LULA00 Electrical and Grid-Support Specifications
ManufacturerStar Charge Americas
Model Number (MPN)SI403LULA00
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.811 kW (3,811 W)
Nominal DC Input (Pdco)3,926 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window180 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current10.9 A
Night Tare Loss6.32 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SI403LULA00
Max Continuous AC Current15.9 A @ 240V
125% Continuous Duty Current19.9 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.19–5.14 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SI403LULA00
Panel ClassRecommended QtyDC Array / Ratio
400W10–13 panels4.0–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Compatible Solar Panels for Star Charge Americas SI403LULA00

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Star Charge Americas SI403LULA00
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — Star Charge Americas SI403LULA00

What size circuit breaker does the Star Charge Americas SI403LULA00 require under NEC 705.12?
At 3.811 kW continuous AC output on 240V (15.9A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Star Charge Americas SI403LULA00?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.811 kW unit with 4.19 kW to 5.14 kW DC of solar modules without exceeding 480V cold Voc.

More Star Charge Americas Inverters

SI803LULA00 (7.641 kW)SI104LULA00 (9.582 kW)All Star Charge Americas Equipment →