Sungrow SC2000UD-US (2014.87 kW)
2000 kVA, 800 Vac, Bi-directional, Grid Support Utility Interactive Inverter with a 2014 kVA liquid immersed distribution transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
2014.87 kW
CEC Weighted Eff.
98%
MPPT / Max DC
1150–1500V / 1500V
NEC 705.12 Breaker
1900A @ 800V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Sungrow |
|---|---|
| Model Number (MPN) | SC2000UD-US |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 2014.87 kW (2,014,870 W) |
| Nominal DC Input (Pdco) | 2,060,200 W |
| Nominal AC Voltage | 800 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 1150 – 1500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1500 Vdc |
| Max DC Input Current | 1648.2 A |
| Night Tare Loss | 157.7 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1454.1 A @ 800V |
|---|---|
| 125% Continuous Duty Current | 1817.6 A |
| Minimum Standard Breaker | 1900 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (2216.36–2720.07 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 5541–6800 panels | 2216.4–2720.0 kW DC |
| 440W | 5037–6182 panels | 2216.3–2720.1 kW DC |
| 550W | 4030–4946 panels | 2216.5–2720.3 kW DC |
CEC-Listed 240V Equivalents to Sungrow SC2000UD-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (2014.87 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Sungrow SC2000UD-US
What size circuit breaker does the Sungrow SC2000UD-US require under NEC 705.12?
At 2014.87 kW continuous AC output on 800V (1454.1A continuous), the 125% continuous duty rule requires a minimum 1900A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Sungrow SC2000UD-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 2014.87 kW unit with 2216.36 kW to 2720.07 kW DC of solar modules without exceeding 1500V cold Voc.