SYL (NINGBO) Battery SP1750UHL (1751.509 kW)
1750 kW, 690 Vac, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
1751.509 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
1000–1500V / 1500V
NEC 705.12 Breaker
1900A @ 690V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SYL (NINGBO) Battery |
|---|---|
| Model Number (MPN) | SP1750UHL |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 1751.509 kW (1,751,509 W) |
| Nominal DC Input (Pdco) | 1,779,210 W |
| Nominal AC Voltage | 690 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 1000 – 1500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1500 Vdc |
| Max DC Input Current | 1547.1 A |
| Night Tare Loss | 119.44 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1465.6 A @ 690V |
|---|---|
| 125% Continuous Duty Current | 1832.0 A |
| Minimum Standard Breaker | 1900 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (1926.66–2364.54 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 4817–5911 panels | 1926.8–2364.4 kW DC |
| 440W | 4379–5374 panels | 1926.8–2364.6 kW DC |
| 550W | 3503–4299 panels | 1926.7–2364.4 kW DC |
CEC-Listed 240V Equivalents to SYL (NINGBO) Battery SP1750UHL
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1751.509 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for SYL (NINGBO) Battery SP1750UHL
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-510-BTB-HV | 510 W | 44.38 V | 31–31 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 21–21 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 | 415 W | 38.47 V | 36–36 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540XM | 540 W | 47.95 V | 28–28 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 38–39 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM | 435 W | 81.4 V | 17–17 per string (-10°C) | Verify Pair |
Engineering FAQ — SYL (NINGBO) Battery SP1750UHL
What size circuit breaker does the SYL (NINGBO) Battery SP1750UHL require under NEC 705.12?
At 1751.509 kW continuous AC output on 690V (1465.6A continuous), the 125% continuous duty rule requires a minimum 1900A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the SYL (NINGBO) Battery SP1750UHL?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1751.509 kW unit with 1926.66 kW to 2364.54 kW DC of solar modules without exceeding 1500V cold Voc.