840 kW, 630 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
796.468 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
915–1200V / 1200V
NEC 705.12 Breaker
1000A @ 630V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | TMEIC |
|---|---|
| Model Number (MPN) | PVU-L0840URN |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 796.468 kW (796,468 W) |
| Nominal DC Input (Pdco) | 808,497 W |
| Nominal AC Voltage | 630 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 915 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 820 A |
| Night Tare Loss | 76.93 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 729.9 A @ 630V |
|---|---|
| 125% Continuous Duty Current | 912.4 A |
| Minimum Standard Breaker | 1000 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (876.11–1075.23 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 2190–2688 panels | 876.0–1075.2 kW DC |
| 440W | 1991–2444 panels | 876.0–1075.4 kW DC |
| 550W | 1593–1955 panels | 876.1–1075.3 kW DC |
CEC-Listed 240V Equivalents to TMEIC PVU-L0840URN
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (796.468 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — TMEIC PVU-L0840URN
What size circuit breaker does the TMEIC PVU-L0840URN require under NEC 705.12?
At 796.468 kW continuous AC output on 630V (729.9A continuous), the 125% continuous duty rule requires a minimum 1000A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the TMEIC PVU-L0840URN?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 796.468 kW unit with 876.11 kW to 1075.23 kW DC of solar modules without exceeding 1200V cold Voc.