Trystar OZPCS-RS35-FB0 (23.446 kW)
24 kVA, 240 Vac, Bi-directional Transformerless Grid Support Utility Interactive Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
23.446 kW
CEC Weighted Eff.
95%
MPPT / Max DC
400–800V / 800V
NEC 705.12 Breaker
125A @ 240V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Trystar |
|---|---|
| Model Number (MPN) | OZPCS-RS35-FB0 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 23.446 kW (23,446 W) |
| Nominal DC Input (Pdco) | 24,640 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 240V, 208V |
| CEC Weighted Efficiency | 95% |
| MPPT Operating Window | 400 – 800 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 41.1 A |
| Night Tare Loss | 1.41 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Bureau Veritas Consumer Products Services |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 97.7 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 122.1 A |
| Minimum Standard Breaker | 125 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (25.79–31.65 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 64–79 panels | 25.6–31.6 kW DC |
| 440W | 59–72 panels | 26.0–31.7 kW DC |
| 550W | 47–58 panels | 25.9–31.9 kW DC |
CEC-Listed 240V Equivalents to Trystar OZPCS-RS35-FB0
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (23.446 kW Hybrid Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Trystar OZPCS-RS35-FB0
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 11–14 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 11–14 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 11–13 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 11–14 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 12–14 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 9–11 per string (-10°C) | Verify Pair |
Engineering FAQ — Trystar OZPCS-RS35-FB0
What size circuit breaker does the Trystar OZPCS-RS35-FB0 require under NEC 705.12?
At 23.446 kW continuous AC output on 240V (97.7A continuous), the 125% continuous duty rule requires a minimum 125A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Trystar OZPCS-RS35-FB0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 23.446 kW unit with 25.79 kW to 31.65 kW DC of solar modules without exceeding 800V cold Voc.