WSTECH APS800-ES-1-440-5 (814.167 kW)
800 kW, 440 Vac, Grid Support Utility Interactive Centeral Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
814.167 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
648–1500V / 1500V
NEC 705.12 Breaker
1400A @ 440V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | WSTECH |
|---|---|
| Model Number (MPN) | APS800-ES-1-440-5 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 814.167 kW (814,167 W) |
| Nominal DC Input (Pdco) | 837,619 W |
| Nominal AC Voltage | 440 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 648 – 1500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1500 Vdc |
| Max DC Input Current | 837.6 A |
| Night Tare Loss | 91.4 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1068.3 A @ 440V |
|---|---|
| 125% Continuous Duty Current | 1335.4 A |
| Minimum Standard Breaker | 1400 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (895.58–1099.13 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 2239–2748 panels | 895.6–1099.2 kW DC |
| 440W | 2035–2498 panels | 895.4–1099.1 kW DC |
| 550W | 1628–1998 panels | 895.4–1098.9 kW DC |
CEC-Listed 240V Equivalents to WSTECH APS800-ES-1-440-5
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (814.167 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for WSTECH APS800-ES-1-440-5
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 17–26 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 18–26 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 18–25 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 18–27 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 18–27 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 14–21 per string (-10°C) | Verify Pair |
Engineering FAQ — WSTECH APS800-ES-1-440-5
What size circuit breaker does the WSTECH APS800-ES-1-440-5 require under NEC 705.12?
At 814.167 kW continuous AC output on 440V (1068.3A continuous), the 125% continuous duty rule requires a minimum 1400A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the WSTECH APS800-ES-1-440-5?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 814.167 kW unit with 895.58 kW to 1099.13 kW DC of solar modules without exceeding 1500V cold Voc.