Reference US Solar ConfigurationFlorida (FL)1:1 Retail

10.4 kW Mission + Enphase + Battery Solar Kit (Florida)

Texas-Built Panels + Smart Whole-Home Storage · Florida Hurricane Backup. Reference Bill of Materials pairing 25× Mission Solar MSX10-415HN0B {C} with 25× Enphase Energy IQ8M-72-2-US and 1× FranklinWH aPower 2 (APR-15KWH-US).

System Size
10.38 kW DC / 8.12 kW AC
Est. Annual Yield
16,254 kWh
Est. Savings (FL)
$2,332/yr
Turnkey Cash Est.
$40,888Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · FL RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (25×) Mission Solar MSX10-415… 10.38 kW DC STC DC 2. INVERTER (25×) Enphase Energy IQ8M-72-2-… 8.12 kW AC · 240V 45A 3. MAIN PANEL & GRID 225A Busbar · NEC 705.12 45A Backfeed · FL Grid 4. HOME ENERGY STORAGE (1×) FranklinWH aPower 2 (APR-15KWH-… · 15.0 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 10.4 kW Mission + Enphase + Battery Solar Kit (Florida)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesMission SolarMSX10-415HN0B {C}25×10.38 kW DC (522 sq ft)Panel Specs →
InverterEnphase EnergyIQ8M-72-2-US25×8.12 kW AC · 1.28× DC/AC · 45A BreakerInverter Specs →
Energy StorageFranklinWHaPower 2 (APR-15KWH-US)1×15 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Florida

Modeled at Florida’s average residential electricity rate (15.1¢/kWh) under 1:1 Retail, this 10.38 kW DC / 8.12 kW AC array produces an estimated 16,254 kWh/year (~$2,332/yr gross bill offset, simple pre-incentive payback ~17.5 years at the $40,888 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 522 sq ft, with a 1.28× DC/AC ratio and a 45A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $40,888 estimate for this 10.38 kW Florida solar kit?
The $40,888 figure is a pre-incentive 2026 turnkey cash estimate covering 25× Mission Solar MSX10-415HN0B {C} panels, 25× Enphase Energy IQ8M-72-2-US, 1× FranklinWH aPower 2 (APR-15KWH-US) (15 kWh), racking, permitting, and licensed installation in Florida. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 10.38 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 8.12 kW continuous AC output, the inverter requires a 45A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 45A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Florida Solar Kits

10.4 kW Qcells + Enphase + Battery Solar Kit (Florida)11.0 kW REC + Tesla + Battery Solar Kit (Florida)10.6 kW Silfab + Sol-Ark + Battery Solar Kit (Florida)10.6 kW JinkoSolar + EG4 + Battery Solar Kit (Florida)All 120 Kits →