Reference US Solar ConfigurationFlorida (FL)1:1 Retail

10.4 kW Qcells + Fronius + Battery Solar Kit (Florida)

Austrian Hybrid Engineering + HV LFP Storage · Florida Hurricane Backup. Reference Bill of Materials pairing 25× Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 with 1× Fronius Primo GEN24 7.7 208-240 and 1× Pylontech Force-H3-102.4/204.8-US.

System Size
10.38 kW DC / 7.69 kW AC
Est. Annual Yield
16,254 kWh
Est. Savings (FL)
$2,332/yr
Turnkey Cash Est.
$37,144Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · FL RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (25×) Qcells (Hanwha) Q.TRON… 10.38 kW DC STC DC 2. INVERTER (1×) Fronius Primo GEN24 7.7 2… 7.69 kW AC · 240V 40A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 40A Backfeed · FL Grid 4. HOME ENERGY STORAGE (1×) Pylontech Force-H3-102.4/204.8-… · 10.2 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 10.4 kW Qcells + Fronius + Battery Solar Kit (Florida)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesQcells (Hanwha)Q.TRON BLK M-G2.D+ 41525×10.38 kW DC (509 sq ft)Panel Specs →
InverterFroniusPrimo GEN24 7.7 208-2401×7.69 kW AC · 1.35× DC/AC · 40A BreakerInverter Specs →
Energy StoragePylontechForce-H3-102.4/204.8-US1×10.2 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Florida

Modeled at Florida’s average residential electricity rate (15.1¢/kWh) under 1:1 Retail, this 10.38 kW DC / 7.69 kW AC array produces an estimated 16,254 kWh/year (~$2,332/yr gross bill offset, simple pre-incentive payback ~15.9 years at the $37,144 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 509 sq ft, with a 1.35× DC/AC ratio and a 40A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $37,144 estimate for this 10.38 kW Florida solar kit?
The $37,144 figure is a pre-incentive 2026 turnkey cash estimate covering 25× Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 panels, 1× Fronius Primo GEN24 7.7 208-240, 1× Pylontech Force-H3-102.4/204.8-US (10.2 kWh), racking, permitting, and licensed installation in Florida. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 10.38 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 7.69 kW continuous AC output, the inverter requires a 40A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 40A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Florida Solar Kits

10.4 kW Qcells + Enphase + Battery Solar Kit (Florida)11.0 kW REC + Tesla + Battery Solar Kit (Florida)10.6 kW Silfab + Sol-Ark + Battery Solar Kit (Florida)10.6 kW JinkoSolar + EG4 + Battery Solar Kit (Florida)All 120 Kits →