Reference US Solar ConfigurationOhio (OH)Avoided Cost

10.6 kW REC + SMA + Battery Solar Kit (Ohio)

German-Engineered Hybrid + Modular LFP Backup · Ohio 4-Season Hybrid. Reference Bill of Materials pairing 24× REC Solar REC440AA Pure-RX-DC with 1× SMA Solar SBSE9.6-US-50 and 1× SMA Solar SMA-ESS-SBS3.8-BYDH7.5.

System Size
10.56 kW DC / 9.57 kW AC
Est. Annual Yield
12,627 kWh
Est. Savings (OH)
$1,321/yr
Turnkey Cash Est.
$38,146Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · OH RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (24×) REC Solar REC440AA Pure… 10.56 kW DC STC DC 2. INVERTER (1×) SMA Solar SBSE9.6-US-50 9.57 kW AC · 240V 50A 3. MAIN PANEL & GRID Line-Side Tap Required 50A Backfeed · OH Grid 4. HOME ENERGY STORAGE (1×) SMA Solar SMA-ESS-SBS3.8-BYDH7.5 · 7.5 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 10.6 kW REC + SMA + Battery Solar Kit (Ohio)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesREC SolarREC440AA Pure-RX-DC24×10.56 kW DC (522 sq ft)Panel Specs →
InverterSMA SolarSBSE9.6-US-501×9.57 kW AC · 1.1× DC/AC · 50A BreakerInverter Specs →
Energy StorageSMA SolarSMA-ESS-SBS3.8-BYDH7.51×7.5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Ohio

Modeled at Ohio’s average residential electricity rate (16.1¢/kWh) under Avoided Cost, this 10.56 kW DC / 9.57 kW AC array produces an estimated 12,627 kWh/year (~$1,321/yr gross bill offset, simple pre-incentive payback ~28.9 years at the $38,146 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 522 sq ft, with a 1.1× DC/AC ratio and a 50A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $38,146 estimate for this 10.56 kW Ohio solar kit?
The $38,146 figure is a pre-incentive 2026 turnkey cash estimate covering 24× REC Solar REC440AA Pure-RX-DC panels, 1× SMA Solar SBSE9.6-US-50, 1× SMA Solar SMA-ESS-SBS3.8-BYDH7.5 (7.5 kWh), racking, permitting, and licensed installation in Ohio. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 10.56 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 9.57 kW continuous AC output, the inverter requires a 50A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 50A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Ohio Solar Kits

10.4 kW Qcells + Enphase + Battery Solar Kit (Ohio)11.0 kW REC + Tesla + Battery Solar Kit (Ohio)10.6 kW Silfab + Sol-Ark + Battery Solar Kit (Ohio)10.6 kW JinkoSolar + EG4 + Battery Solar Kit (Ohio)All 120 Kits →