Reference US Solar ConfigurationGeorgia (GA)Avoided Cost

12.2 kW LONGi + Solis + Battery Solar Kit (Georgia)

High-Efficiency Value Hybrid Backup · Georgia Heavy Cooling. Reference Bill of Materials pairing 29× LONGi Solar LR5-54HABD-420M with 1× Solis (Ginlong) S6-EH1P9.9K-H-US and 2× Fortress Power DuraRack DC energy storage system-10.8P2.

System Size
12.18 kW DC / 9.99 kW AC
Est. Annual Yield
17,685 kWh
Est. Savings (GA)
$2,303/yr
Turnkey Cash Est.
$54,665Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · GA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (29×) LONGi Solar LR5-54HABD-… 12.18 kW DC STC DC 2. INVERTER (1×) Solis (Ginlong) S6-EH1P9.… 9.99 kW AC · 240V 60A 3. MAIN PANEL & GRID Line-Side Tap Required 60A Backfeed · GA Grid 4. HOME ENERGY STORAGE (2×) Fortress Power DuraRack DC ener… · 21.5 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 12.2 kW LONGi + Solis + Battery Solar Kit (Georgia)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesLONGi SolarLR5-54HABD-420M29×12.18 kW DC (593 sq ft)Panel Specs →
InverterSolis (Ginlong)S6-EH1P9.9K-H-US1×9.99 kW AC · 1.22× DC/AC · 60A BreakerInverter Specs →
Energy StorageFortress PowerDuraRack DC energy storage system-10.8P22×21.5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Georgia

Modeled at Georgia’s average residential electricity rate (14.8¢/kWh) under Avoided Cost, this 12.18 kW DC / 9.99 kW AC array produces an estimated 17,685 kWh/year (~$2,303/yr gross bill offset, simple pre-incentive payback ~23.7 years at the $54,665 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 593 sq ft, with a 1.22× DC/AC ratio and a 60A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $54,665 estimate for this 12.18 kW Georgia solar kit?
The $54,665 figure is a pre-incentive 2026 turnkey cash estimate covering 29× LONGi Solar LR5-54HABD-420M panels, 1× Solis (Ginlong) S6-EH1P9.9K-H-US, 2× Fortress Power DuraRack DC energy storage system-10.8P2 (21.5 kWh), racking, permitting, and licensed installation in Georgia. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 12.18 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 9.99 kW continuous AC output, the inverter requires a 60A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 60A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Georgia Solar Kits

12.0 kW Qcells + Enphase + Battery Solar Kit (Georgia)12.3 kW REC + Tesla + Battery Solar Kit (Georgia)12.3 kW Silfab + Sol-Ark + Battery Solar Kit (Georgia)13.2 kW JinkoSolar + EG4 + Battery Solar Kit (Georgia)All 120 Kits →