Texas-Built Panels + Smart Whole-Home Storage · New York Cold-Climate VDER. Reference Bill of Materials pairing 20× Mission Solar MSX10-415HN0B {C} with 20× Enphase Energy IQ8M-72-2-US and 1× FranklinWH aPower 2 (APR-15KWH-US).

System Size
8.3 kW DC / 6.5 kW AC
Est. Annual Yield
9,925 kWh
Est. Savings (NY)
$2,122/yr
Turnkey Cash Est.
$39,630Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · NY RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (20×) Mission Solar MSX10-415… 8.30 kW DC STC DC 2. INVERTER (20×) Enphase Energy IQ8M-72-2-… 6.50 kW AC · 240V 35A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 35A Backfeed · NY Grid 4. HOME ENERGY STORAGE (1×) FranklinWH aPower 2 (APR-15KWH-… · 15.0 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 8.3 kW Mission + Enphase + Battery Solar Kit (New York)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesMission SolarMSX10-415HN0B {C}20×8.3 kW DC (418 sq ft)Panel Specs →
InverterEnphase EnergyIQ8M-72-2-US20×6.5 kW AC · 1.28× DC/AC · 35A BreakerInverter Specs →
Energy StorageFranklinWHaPower 2 (APR-15KWH-US)1×15 kWh usable capacityBattery Specs →

Cost & Sizing Notes for New York

Modeled at New York’s average residential electricity rate (24.3¢/kWh) under VDER / Value Stack, this 8.3 kW DC / 6.5 kW AC array produces an estimated 9,925 kWh/year (~$2,122/yr gross bill offset, simple pre-incentive payback ~18.7 years at the $39,630 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 418 sq ft, with a 1.28× DC/AC ratio and a 35A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $39,630 estimate for this 8.3 kW New York solar kit?
The $39,630 figure is a pre-incentive 2026 turnkey cash estimate covering 20× Mission Solar MSX10-415HN0B {C} panels, 20× Enphase Energy IQ8M-72-2-US, 1× FranklinWH aPower 2 (APR-15KWH-US) (15 kWh), racking, permitting, and licensed installation in New York. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 8.3 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 6.5 kW continuous AC output, the inverter requires a 35A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 35A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference New York Solar Kits

8.3 kW Qcells + Enphase Solar Kit (New York)11.0 kW REC + Tesla + Battery Solar Kit (New York)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (New York)8.8 kW JinkoSolar + EG4 Solar Kit (New York)All 120 Kits →