Reference US Solar ConfigurationNew York (NY)VDER / Value Stack

11.0 kW REC + Tesla + Battery Solar Kit (New York)

NEM 3.0 & Whole-Home Integrated Flagship · New York Cold-Climate VDER. Reference Bill of Materials pairing 25× REC Solar REC440AA Pure-RX-DC with 1× Tesla Energy 1707000-XX-Y and 1× Tesla Energy Powerwall 3 (1707000-XX-Y).

System Size
11 kW DC / 9.99 kW AC
Est. Annual Yield
13,153 kWh
Est. Savings (NY)
$2,813/yr
Turnkey Cash Est.
$46,830Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · NY RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (25×) REC Solar REC440AA Pure… 11.00 kW DC STC DC 2. INVERTER (1×) Tesla Energy 1707000-XX-Y 9.99 kW AC · 240V 60A 3. MAIN PANEL & GRID Line-Side Tap Required 60A Backfeed · NY Grid 4. HOME ENERGY STORAGE (1×) Tesla Energy Powerwall 3 (17070… · 13.5 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 11.0 kW REC + Tesla + Battery Solar Kit (New York)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesREC SolarREC440AA Pure-RX-DC25×11 kW DC (544 sq ft)Panel Specs →
InverterTesla Energy1707000-XX-Y1×9.99 kW AC · 1.1× DC/AC · 60A BreakerInverter Specs →
Energy StorageTesla EnergyPowerwall 3 (1707000-XX-Y)1×13.5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for New York

Modeled at New York’s average residential electricity rate (24.3¢/kWh) under VDER / Value Stack, this 11 kW DC / 9.99 kW AC array produces an estimated 13,153 kWh/year (~$2,813/yr gross bill offset, simple pre-incentive payback ~16.6 years at the $46,830 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 544 sq ft, with a 1.1× DC/AC ratio and a 60A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $46,830 estimate for this 11 kW New York solar kit?
The $46,830 figure is a pre-incentive 2026 turnkey cash estimate covering 25× REC Solar REC440AA Pure-RX-DC panels, 1× Tesla Energy 1707000-XX-Y, 1× Tesla Energy Powerwall 3 (1707000-XX-Y) (13.5 kWh), racking, permitting, and licensed installation in New York. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 11 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 9.99 kW continuous AC output, the inverter requires a 60A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 60A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference New York Solar Kits

8.3 kW Qcells + Enphase Solar Kit (New York)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (New York)8.8 kW JinkoSolar + EG4 Solar Kit (New York)8.6 kW Canadian + SolarEdge + Battery Solar Kit (New York)All 120 Kits →