Reference US Solar ConfigurationNew York (NY)VDER / Value Stack

8.5 kW Trina + Hoymiles + Battery Solar Kit (New York)

Cost-Optimized Microinverter + Heavy LFP · New York Cold-Climate VDER. Reference Bill of Materials pairing 19× Trina Solar TSM-445NEG9RH.25 with 19× Hoymiles HMS-400-1A-NA and 1× Fortress Power eForce DC energy storage system-9.6P1-0.

System Size
8.46 kW DC / 6.88 kW AC
Est. Annual Yield
10,116 kWh
Est. Savings (NY)
$1,598/yr
Turnkey Cash Est.
$35,914Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · NY RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (19×) Trina Solar TSM-445NEG9… 8.46 kW DC STC DC 2. INVERTER (19×) Hoymiles HMS-400-1A-NA 6.88 kW AC · 240V 40A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 40A Backfeed · NY Grid 4. HOME ENERGY STORAGE (1×) Fortress Power eForce DC energy… · 9.6 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 8.5 kW Trina + Hoymiles + Battery Solar Kit (New York)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesTrina SolarTSM-445NEG9RH.2519×8.46 kW DC (405 sq ft)Panel Specs →
InverterHoymilesHMS-400-1A-NA19×6.88 kW AC · 1.23× DC/AC · 40A BreakerInverter Specs →
Energy StorageFortress PowereForce DC energy storage system-9.6P1-01×9.6 kWh usable capacityBattery Specs →

Cost & Sizing Notes for New York

Modeled at New York’s average residential electricity rate (24.3¢/kWh) under VDER / Value Stack, this 8.46 kW DC / 6.88 kW AC array produces an estimated 10,116 kWh/year (~$1,598/yr gross bill offset, simple pre-incentive payback ~22.5 years at the $35,914 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 405 sq ft, with a 1.23× DC/AC ratio and a 40A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $35,914 estimate for this 8.46 kW New York solar kit?
The $35,914 figure is a pre-incentive 2026 turnkey cash estimate covering 19× Trina Solar TSM-445NEG9RH.25 panels, 19× Hoymiles HMS-400-1A-NA, 1× Fortress Power eForce DC energy storage system-9.6P1-0 (9.6 kWh), racking, permitting, and licensed installation in New York. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 8.46 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 6.88 kW continuous AC output, the inverter requires a 40A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 40A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference New York Solar Kits

8.3 kW Qcells + Enphase Solar Kit (New York)11.0 kW REC + Tesla + Battery Solar Kit (New York)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (New York)8.8 kW JinkoSolar + EG4 Solar Kit (New York)All 120 Kits →