AE Solar AE595CMD-144BDS
595 W, 144 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
595W / 567.2W
Efficiency
23.06%
Voc / Vmp
51.9V / 43.3V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | AE Solar |
|---|---|
| Model Number (MPN) | AE595CMD-144BDS |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 595 W |
| Real-World Output (PTC) | 567.2 W (95.3% of STC) |
| Module Efficiency | 23.06% (230.6 W/m²) |
| Open-Circuit Voltage (Voc) | 51.9 V |
| Maximum Power Voltage (Vmp) | 43.3 V |
| Short-Circuit Current (Isc) | 14.26 A (NEC 1.25× = 17.82 A) |
| Maximum Power Current (Imp) | 13.75 A |
| Temp. Coeff. Power (γPmax) | -0.282 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.243 %/°C |
| Temp. Coeff. Current (αIsc) | +0.033 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.58 m² (27.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.243%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 51.9 V | 11 | 19 |
| 0°C / 32°F Freezing / Mild Winter | 55.05 V | 10 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 56.31 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 57.58 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 58.84 V | 10 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.54 kW | 305 sq ft (28.4 m²) |
| 8 kW | 14 panels | 8.33 kW | 389 sq ft (36.1 m²) |
| 10 kW | 17 panels | 10.12 kW | 472 sq ft (43.9 m²) |
| 12 kW | 21 panels | 12.49 kW | 583 sq ft (54.2 m²) |
Compatible CEC-Listed Inverters for AE595CMD-144BDS
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.55 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This AE Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| AE570CMD-144BDS | 570 W | 542.9 W | 51.2 V | 13.91 A | 22.09% |
| AE575CMD-144BDS | 575 W | 547.7 W | 51.3 V | 13.98 A | 22.29% |
| AE580CMD-144BDS | 580 W | 552.6 W | 51.5 V | 14.05 A | 22.48% |
| AE585CMD-144BDS | 585 W | 557.5 W | 51.6 V | 14.13 A | 22.67% |
| AE590CMD-144BDS | 590 W | 562.3 W | 51.8 V | 14.19 A | 22.87% |
Engineering FAQ — AE Solar AE595CMD-144BDS
How many AE Solar AE595CMD-144BDS panels can fit in one 600V string?
At -10°C (14°F) ambient, the AE595CMD-144BDS open-circuit voltage rises from 51.9V to 56.31V (using βVoc -0.243%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the AE Solar AE595CMD-144BDS?
Rated at 595W STC, the AE595CMD-144BDS carries a 567.2W PTC rating (95.3% PTC/STC ratio) and 23.06% module efficiency across 2.58 m² (27.8 sq ft).
Is the AE Solar AE595CMD-144BDS listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.