APsystems official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

APsystems ELS-3K (3.685 kW)

3.68 kVA, 240 Vac, Grid Support Utility Interactive Bi-directional Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.685 kW
CEC Weighted Eff.
94%
MPPT / Max DC
52–500V / 600V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems ELS-3K — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 52–500 Vdc 52V 500V MAX 600V PV DC INPUT ≤ 600V DC 3.685 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

APsystems ELS-3K Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)ELS-3K
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.685 kW (3,685 W)
Nominal DC Input (Pdco)3,903 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94%
MPPT Operating Window52 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current69.7 A
Night Tare Loss4.27 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for ELS-3K
Max Continuous AC Current15.4 A @ 240V
125% Continuous Duty Current19.3 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.05–4.97 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for ELS-3K
Panel ClassRecommended QtyDC Array / Ratio
400W10–12 panels4.0–4.8 kW DC
440W9–11 panels4.0–4.8 kW DC
550W7–9 panels3.9–5.0 kW DC

Compatible Solar Panels for APsystems ELS-3K

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for APsystems ELS-3K
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V2–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V2–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V2–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V2–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V2–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V2–8 per string (-10°C)Verify Pair

Engineering FAQ — APsystems ELS-3K

What size circuit breaker does the APsystems ELS-3K require under NEC 705.12?
At 3.685 kW continuous AC output on 240V (15.4A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems ELS-3K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.685 kW unit with 4.05 kW to 4.97 kW DC of solar modules without exceeding 600V cold Voc.