Aptos Solar DNA-132-BFN10-515W-DG
515 W, 132 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
515W / 488.4W
Efficiency
21.73%
Voc / Vmp
46.28V / 38.27V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Aptos Solar |
|---|---|
| Model Number (MPN) | DNA-132-BFN10-515W-DG |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 515 W |
| Real-World Output (PTC) | 488.4 W (94.8% of STC) |
| Module Efficiency | 21.73% (217.3 W/m²) |
| Open-Circuit Voltage (Voc) | 46.28 V |
| Maximum Power Voltage (Vmp) | 38.27 V |
| Short-Circuit Current (Isc) | 14.21 A (NEC 1.25× = 17.76 A) |
| Maximum Power Current (Imp) | 13.45 A |
| Temp. Coeff. Power (γPmax) | -0.298 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.37 m² (25.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 46.28 V | 12 | 21 |
| 0°C / 32°F Freezing / Mild Winter | 49.06 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 50.17 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 51.28 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 52.39 V | 11 | 19 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.18 kW | 306 sq ft (28.4 m²) |
| 8 kW | 16 panels | 8.24 kW | 408 sq ft (37.9 m²) |
| 10 kW | 20 panels | 10.30 kW | 510 sq ft (47.4 m²) |
| 12 kW | 24 panels | 12.36 kW | 612 sq ft (56.9 m²) |
Compatible CEC-Listed Inverters for DNA-132-BFN10-515W-DG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.34 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Aptos Solar Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| DNA-132-BFN10-520W-DG | 520 W | 493.3 W | 46.44 V | 14.27 A | 21.94% |
| DNA-132-BFN10-525W-DG | 525 W | 498.1 W | 46.57 V | 14.35 A | 22.15% |
| DNA-132-BFN10-530W-DG | 530 W | 503 W | 46.72 V | 14.41 A | 22.36% |
Engineering FAQ — Aptos Solar DNA-132-BFN10-515W-DG
How many Aptos Solar DNA-132-BFN10-515W-DG panels can fit in one 600V string?
At -10°C (14°F) ambient, the DNA-132-BFN10-515W-DG open-circuit voltage rises from 46.28V to 50.17V (using βVoc -0.24%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Aptos Solar DNA-132-BFN10-515W-DG?
Rated at 515W STC, the DNA-132-BFN10-515W-DG carries a 488.4W PTC rating (94.8% PTC/STC ratio) and 21.73% module efficiency across 2.37 m² (25.5 sq ft).
Is the Aptos Solar DNA-132-BFN10-515W-DG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.