Aptos Solar DNA-144-BFN10-580W-DG
580 W, 144 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
580W / 550.5W
Efficiency
22.48%
Voc / Vmp
51.02V / 42.37V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Aptos Solar |
|---|---|
| Model Number (MPN) | DNA-144-BFN10-580W-DG |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 580 W |
| Real-World Output (PTC) | 550.5 W (94.9% of STC) |
| Module Efficiency | 22.48% (224.8 W/m²) |
| Open-Circuit Voltage (Voc) | 51.02 V |
| Maximum Power Voltage (Vmp) | 42.37 V |
| Short-Circuit Current (Isc) | 14.47 A (NEC 1.25× = 18.09 A) |
| Maximum Power Current (Imp) | 13.69 A |
| Temp. Coeff. Power (γPmax) | -0.298 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.58 m² (27.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 51.02 V | 11 | 19 |
| 0°C / 32°F Freezing / Mild Winter | 54.08 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 55.31 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.53 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.75 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.38 kW | 305 sq ft (28.4 m²) |
| 8 kW | 14 panels | 8.12 kW | 389 sq ft (36.1 m²) |
| 10 kW | 18 panels | 10.44 kW | 500 sq ft (46.4 m²) |
| 12 kW | 21 panels | 12.18 kW | 583 sq ft (54.2 m²) |
Compatible CEC-Listed Inverters for DNA-144-BFN10-580W-DG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.51 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Aptos Solar Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| DNA-144-BFN10-565W-DG | 565 W | 535.9 W | 50.6 V | 14.23 A | 21.9% |
| DNA-144-BFN10-570W-DG | 570 W | 540.8 W | 50.74 V | 14.31 A | 22.09% |
| DNA-144-BFN10-575W-DG | 575 W | 545.6 W | 50.88 V | 14.39 A | 22.29% |
Engineering FAQ — Aptos Solar DNA-144-BFN10-580W-DG
How many Aptos Solar DNA-144-BFN10-580W-DG panels can fit in one 600V string?
At -10°C (14°F) ambient, the DNA-144-BFN10-580W-DG open-circuit voltage rises from 51.02V to 55.31V (using βVoc -0.24%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Aptos Solar DNA-144-BFN10-580W-DG?
Rated at 580W STC, the DNA-144-BFN10-580W-DG carries a 550.5W PTC rating (94.9% PTC/STC ratio) and 22.48% module efficiency across 2.58 m² (27.8 sq ft).
Is the Aptos Solar DNA-144-BFN10-580W-DG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.