Arka Energy AEP-821-00020-A (90W)
90 W, 26 half-cut cell monocrystalline module, 600V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
90W / 83.5W
Efficiency
15.25%
Voc / Vmp
8.84V / 7.3V
Max String (600V)
62 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Arka Energy |
|---|---|
| Model Number (MPN) | AEP-821-00020-A |
| Cell Technology | Mono-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 90 W |
| Real-World Output (PTC) | 83.5 W (92.8% of STC) |
| Module Efficiency | 15.25% (152.5 W/m²) |
| Open-Circuit Voltage (Voc) | 8.84 V |
| Maximum Power Voltage (Vmp) | 7.3 V |
| Short-Circuit Current (Isc) | 13.4 A (NEC 1.25× = 16.75 A) |
| Maximum Power Current (Imp) | 12.12 A |
| Temp. Coeff. Power (γPmax) | -0.351 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.254 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 44.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 0.59 m² (6.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.254%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 8.84 V | 67 | 113 |
| 0°C / 32°F Freezing / Mild Winter | 9.4 V | 63 | 106 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 9.63 V | 62 | 103 |
| -20°C / -4°F Northeast / Midwest Winter | 9.85 V | 60 | 101 |
| -30°C / -22°F Northern Plains / Mountain | 10.07 V | 59 | 99 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 67 panels | 6.03 kW | 425 sq ft (39.5 m²) |
| 8 kW | 89 panels | 8.01 kW | 565 sq ft (52.5 m²) |
| 10 kW | 112 panels | 10.08 kW | 711 sq ft (66.1 m²) |
| 12 kW | 134 panels | 12.06 kW | 851 sq ft (79.1 m²) |
CEC-Listed US Equivalents to Arka Energy AEP-821-00020-A
Looking to build a compliant US residential system with comparable wattage (90W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for AEP-821-00020-A
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 4–62 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 14–49 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 7–83 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 7–51 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 7–51 panels/string at -10°C | Verify Pair |
Engineering FAQ — Arka Energy AEP-821-00020-A
How many Arka Energy AEP-821-00020-A panels can fit in one 600V string?
At -10°C (14°F) ambient, the AEP-821-00020-A open-circuit voltage rises from 8.84V to 9.63V (using βVoc -0.254%/°C), allowing up to 62 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Arka Energy AEP-821-00020-A?
Rated at 90W STC, the AEP-821-00020-A carries a 83.5W PTC rating (92.8% PTC/STC ratio) and 15.25% module efficiency across 0.59 m² (6.4 sq ft).
Is the Arka Energy AEP-821-00020-A listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.