Astronergy (CHINT) CHSM72M(DG)/F-BH-520
520 W, 144 half-cut cell bifacial dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
520W / 482W
Efficiency
20.72%
Voc / Vmp
49V / 41V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Astronergy (CHINT) |
|---|---|
| Model Number (MPN) | CHSM72M(DG)/F-BH-520 |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 520 W |
| Real-World Output (PTC) | 482 W (92.7% of STC) |
| Module Efficiency | 20.72% (207.2 W/m²) |
| Open-Circuit Voltage (Voc) | 49 V |
| Maximum Power Voltage (Vmp) | 41 V |
| Short-Circuit Current (Isc) | 13.58 A (NEC 1.25× = 16.98 A) |
| Maximum Power Current (Imp) | 12.69 A |
| Temp. Coeff. Power (γPmax) | -0.333 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.253 %/°C |
| Temp. Coeff. Current (αIsc) | +0.032 %/°C |
| Nominal Cell Temp (NOCT) | 48 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.51 m² (27.0 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.253%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.1 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.34 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.58 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 55.82 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.24 kW | 324 sq ft (30.1 m²) |
| 8 kW | 16 panels | 8.32 kW | 432 sq ft (40.2 m²) |
| 10 kW | 20 panels | 10.40 kW | 540 sq ft (50.2 m²) |
| 12 kW | 24 panels | 12.48 kW | 648 sq ft (60.2 m²) |
Compatible CEC-Listed Inverters for CHSM72M(DG)/F-BH-520
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.35 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Astronergy (CHINT) Series (10 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| CHSM72M(DG)/F-BH-525 | 525 W | 486.8 W | 49.2 V | 13.65 A | 20.92% |
| CHSM72M(DG)/F-BH-530 | 530 W | 491.5 W | 49.3 V | 13.72 A | 21.12% |
| CHSM72M(DG)/F-BH-535 | 535 W | 496.3 W | 49.5 V | 13.79 A | 21.31% |
| CHSM72M(DG)/F-BH-540 | 540 W | 501.1 W | 49.6 V | 13.86 A | 21.51% |
| CHSM72M(DG)/F-BH-545 | 545 W | 505.9 W | 49.8 V | 13.93 A | 21.71% |
| CHSM72M(DG)/F-BH-550 | 550 W | 510.7 W | 49.9 V | 14 A | 21.91% |
| CHSM72M(DG)/F-BH-555 | 555 W | 515.4 W | 50.1 V | 14.07 A | 22.11% |
| CHSM72M(DG)/F-BH-560 | 560 W | 520.2 W | 50.2 V | 14.14 A | 22.31% |
| CHSM72M(DG)/F-BH-565 | 565 W | 525 W | 50.3 V | 14.21 A | 22.51% |
Engineering FAQ — Astronergy (CHINT) CHSM72M(DG)/F-BH-520
How many Astronergy (CHINT) CHSM72M(DG)/F-BH-520 panels can fit in one 600V string?
At -10°C (14°F) ambient, the CHSM72M(DG)/F-BH-520 open-circuit voltage rises from 49V to 53.34V (using βVoc -0.253%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Astronergy (CHINT) CHSM72M(DG)/F-BH-520?
Rated at 520W STC, the CHSM72M(DG)/F-BH-520 carries a 482W PTC rating (92.7% PTC/STC ratio) and 20.72% module efficiency across 2.51 m² (27.0 sq ft).
Is the Astronergy (CHINT) CHSM72M(DG)/F-BH-520 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.