AUO PM024NB8_195
195 W, monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
195W / 183.2W
Efficiency
21.2%
Voc / Vmp
17.53V / 14.49V
Max String (600V)
31 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | AUO |
|---|---|
| Model Number (MPN) | PM024NB8_195 |
| Cell Technology | Mono-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 195 W |
| Real-World Output (PTC) | 183.2 W (93.9% of STC) |
| Module Efficiency | 21.2% (212 W/m²) |
| Open-Circuit Voltage (Voc) | 17.53 V |
| Maximum Power Voltage (Vmp) | 14.49 V |
| Short-Circuit Current (Isc) | 14.22 A (NEC 1.25× = 17.78 A) |
| Maximum Power Current (Imp) | 13.51 A |
| Temp. Coeff. Power (γPmax) | -0.316 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.238 %/°C |
| Temp. Coeff. Current (αIsc) | +0.037 %/°C |
| Nominal Cell Temp (NOCT) | 45.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 0.92 m² (9.9 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.238%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 17.53 V | 34 | 57 |
| 0°C / 32°F Freezing / Mild Winter | 18.57 V | 32 | 53 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 18.99 V | 31 | 52 |
| -20°C / -4°F Northeast / Midwest Winter | 19.41 V | 30 | 51 |
| -30°C / -22°F Northern Plains / Mountain | 19.82 V | 30 | 50 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 31 panels | 6.04 kW | 307 sq ft (28.5 m²) |
| 8 kW | 42 panels | 8.19 kW | 416 sq ft (38.6 m²) |
| 10 kW | 52 panels | 10.14 kW | 515 sq ft (47.8 m²) |
| 12 kW | 62 panels | 12.09 kW | 614 sq ft (57.0 m²) |
CEC-Listed US Equivalents to AUO PM024NB8_195
Looking to build a compliant US residential system with comparable wattage (195W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for PM024NB8_195
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 4–31 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 14–25 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-72-2-US | Microinverter | 0.19 kW | 96.5% | 1:1 micro pairing (1.03 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 7–42 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 7–26 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 7–26 panels/string at -10°C | Verify Pair |
Engineering FAQ — AUO PM024NB8_195
How many AUO PM024NB8_195 panels can fit in one 600V string?
At -10°C (14°F) ambient, the PM024NB8_195 open-circuit voltage rises from 17.53V to 18.99V (using βVoc -0.238%/°C), allowing up to 31 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the AUO PM024NB8_195?
Rated at 195W STC, the PM024NB8_195 carries a 183.2W PTC rating (93.9% PTC/STC ratio) and 21.2% module efficiency across 0.92 m² (9.9 sq ft).
Is the AUO PM024NB8_195 listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.