AXITEC AC-585TGB/144TS
585 W, 144 half-cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
585W / 556.2W
Efficiency
23.21%
Voc / Vmp
51.58V / 42.72V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | AXITEC |
|---|---|
| Model Number (MPN) | AC-585TGB/144TS |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 585 W |
| Real-World Output (PTC) | 556.2 W (95.1% of STC) |
| Module Efficiency | 23.21% (232.1 W/m²) |
| Open-Circuit Voltage (Voc) | 51.58 V |
| Maximum Power Voltage (Vmp) | 42.72 V |
| Short-Circuit Current (Isc) | 14.41 A (NEC 1.25× = 18.01 A) |
| Maximum Power Current (Imp) | 13.7 A |
| Temp. Coeff. Power (γPmax) | -0.295 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.251 %/°C |
| Temp. Coeff. Current (αIsc) | +0.043 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.52 m² (27.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.251%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 51.58 V | 11 | 19 |
| 0°C / 32°F Freezing / Mild Winter | 54.82 V | 10 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 56.11 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 57.41 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 58.7 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.43 kW | 298 sq ft (27.7 m²) |
| 8 kW | 14 panels | 8.19 kW | 380 sq ft (35.3 m²) |
| 10 kW | 18 panels | 10.53 kW | 488 sq ft (45.4 m²) |
| 12 kW | 21 panels | 12.29 kW | 570 sq ft (52.9 m²) |
Compatible CEC-Listed Inverters for AC-585TGB/144TS
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This AXITEC Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| AC-555TGB/144TS | 555 W | 527 W | 50.7 V | 14.01 A | 22.02% |
| AC-560TGB/144TS | 560 W | 531.9 W | 50.84 V | 14.07 A | 22.22% |
| AC-565TGB/144TS | 565 W | 536.7 W | 50.98 V | 14.13 A | 22.42% |
| AC-570TGB/144TS | 570 W | 541.6 W | 51.13 V | 14.2 A | 22.62% |
| AC-575TGB/144TS | 575 W | 546.4 W | 51.28 V | 14.27 A | 22.82% |
| AC-580TGB/144TS | 580 W | 551.3 W | 51.43 V | 14.34 A | 23.02% |
| AC-590TGB/144TS | 590 W | 561 W | 51.7 V | 14.48 A | 23.41% |
Engineering FAQ — AXITEC AC-585TGB/144TS
How many AXITEC AC-585TGB/144TS panels can fit in one 600V string?
At -10°C (14°F) ambient, the AC-585TGB/144TS open-circuit voltage rises from 51.58V to 56.11V (using βVoc -0.251%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the AXITEC AC-585TGB/144TS?
Rated at 585W STC, the AC-585TGB/144TS carries a 556.2W PTC rating (95.1% PTC/STC ratio) and 23.21% module efficiency across 2.52 m² (27.1 sq ft).
Is the AXITEC AC-585TGB/144TS listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.