Boviet Solar BVM7613M-570-H-HC
570 W, 156 half-cut cell monocrystalline module, black or white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
570W / 537.6W
Efficiency
20.36%
Voc / Vmp
53.83V / 45.51V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Boviet Solar |
|---|---|
| Model Number (MPN) | BVM7613M-570-H-HC |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 570 W |
| Real-World Output (PTC) | 537.6 W (94.3% of STC) |
| Module Efficiency | 20.36% (203.6 W/m²) |
| Open-Circuit Voltage (Voc) | 53.83 V |
| Maximum Power Voltage (Vmp) | 45.51 V |
| Short-Circuit Current (Isc) | 13.4 A (NEC 1.25× = 16.75 A) |
| Maximum Power Current (Imp) | 12.55 A |
| Temp. Coeff. Power (γPmax) | -0.334 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.258 %/°C |
| Temp. Coeff. Current (αIsc) | +0.048 %/°C |
| Nominal Cell Temp (NOCT) | 42.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.8 m² (30.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.258%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.83 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 57.3 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 58.69 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 60.08 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 61.47 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.27 kW | 332 sq ft (30.8 m²) |
| 8 kW | 15 panels | 8.55 kW | 452 sq ft (42.0 m²) |
| 10 kW | 18 panels | 10.26 kW | 543 sq ft (50.4 m²) |
| 12 kW | 22 panels | 12.54 kW | 663 sq ft (61.6 m²) |
Compatible CEC-Listed Inverters for BVM7613M-570-H-HC
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Boviet Solar Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| BVM7613M-575-H-HC | 575 W | 542.4 W | 53.9 V | 13.48 A | 20.54% |
| BVM7613M-580-H-HC | 580 W | 547.2 W | 53.98 V | 13.56 A | 20.71% |
| BVM7613M-585-H-HC | 585 W | 552.1 W | 54.07 V | 13.64 A | 20.89% |
| BVM7613M-590-H-HC | 590 W | 556.9 W | 54.15 V | 13.72 A | 21.07% |
| BVM7613M-595-H-HC | 595 W | 561.7 W | 54.24 V | 13.81 A | 21.25% |
| BVM7613M-600-H-HC | 600 W | 566.6 W | 54.31 V | 14.08 A | 21.43% |
| BVM7613M-605-H-HC | 605 W | 571.4 W | 54.4 V | 14.16 A | 21.61% |
Engineering FAQ — Boviet Solar BVM7613M-570-H-HC
How many Boviet Solar BVM7613M-570-H-HC panels can fit in one 600V string?
At -10°C (14°F) ambient, the BVM7613M-570-H-HC open-circuit voltage rises from 53.83V to 58.69V (using βVoc -0.258%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Boviet Solar BVM7613M-570-H-HC?
Rated at 570W STC, the BVM7613M-570-H-HC carries a 537.6W PTC rating (94.3% PTC/STC ratio) and 20.36% module efficiency across 2.8 m² (30.1 sq ft).
Is the Boviet Solar BVM7613M-570-H-HC listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.