EE CEC-Listed · ResidentialUL 61730

Elin Energy (Sirius PV) ELNSM54M-HC-LV-390

390 W, 108 half-cut cell monocrystalline module, black or white backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
390W / 367.3W
Efficiency
20.1%
Voc / Vmp
36.92V / 30.57V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Elin Energy (Sirius PV) ELNSM54M-HC-LV-390 — Illustrative category photo — not this exact model · Real monocrystalline rooftop solar array
Illustrative category photo — not this exact model · Real monocrystalline rooftop solar arrayWikimedia Commons — File:Polycrystalline solar panel mj1.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (108 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 39.94V Isc 13.4A MPP 390W (30.57V · 12.79A) Voc 36.92V DC Voltage (V) · Efficiency 20.1%

Electrical & Thermal Specifications (STC)

Elin Energy (Sirius PV) ELNSM54M-HC-LV-390 Electrical and Mechanical Specifications
ManufacturerElin Energy (Sirius PV)
Model Number (MPN)ELNSM54M-HC-LV-390
Cell TechnologyMono-c-Si · 108 cells
Nameplate Power (Pmax STC)390 W
Real-World Output (PTC)367.3 W (94.2% of STC)
Module Efficiency20.1% (201 W/m²)
Open-Circuit Voltage (Voc)36.92 V
Maximum Power Voltage (Vmp)30.57 V
Short-Circuit Current (Isc)13.4 A (NEC 1.25× = 16.75 A)
Maximum Power Current (Imp)12.79 A
Temp. Coeff. Power (γPmax)-0.332 %/°C
Temp. Coeff. Voltage (βVoc)-0.234 %/°C
Temp. Coeff. Current (αIsc)+0.045 %/°C
Nominal Cell Temp (NOCT)43.2 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")
Surface Area1.94 m² (20.9 sq ft)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.234%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for ELNSM54M-HC-LV-390
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
36.92 V1627
0°C / 32°F
Freezing / Mild Winter
39.08 V1525
-10°C / 14°F
TX / Southeast / Mid-Atlantic
39.94 V1525
-20°C / -4°F
Northeast / Midwest Winter
40.81 V1424
-30°C / -22°F
Northern Plains / Mountain
41.67 V1423

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using ELNSM54M-HC-LV-390
Target SizePanels NeededActual DCRoof Footprint
6 kW16 panels6.24 kW334 sq ft (31.0 m²)
8 kW21 panels8.19 kW439 sq ft (40.7 m²)
10 kW26 panels10.14 kW543 sq ft (50.4 m²)
12 kW31 panels12.09 kW647 sq ft (60.1 m²)

Compatible CEC-Listed Inverters for ELNSM54M-HC-LV-390

Open full string calculator with this panel →
Compatible US-Certified Inverters for Elin Energy (Sirius PV) ELNSM54M-HC-LV-390
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–15 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%8–12 panels/string at -10°CVerify Pair
Enphase Energy IQ6PLUS-ACB-LLMicroinverter0.27 kW95.5%1:1 micro pairing (1.44 DC/AC ratio)Verify Pair
Fronius Primo 3.8-1 208-240String3.8 kW95.5%4–20 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%4–12 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%4–12 panels/string at -10°CVerify Pair

Other Power Classes in This Elin Energy (Sirius PV) Series (10 total CEC variants)

Sibling Power Classes in the Elin Energy (Sirius PV) Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
ELNSM54M-HC-LV-395395 W372.1 W37.02 V13.5 A20.36%
ELNSM54M-HC-LV-400400 W376.9 W37.12 V13.6 A20.62%
ELNSM54M-HC-LV-405405 W381.8 W37.22 V13.7 A20.88%
ELNSM54M-HC-LV-410410 W386.6 W37.32 V13.8 A21.13%
ELNSM54M-HC-LV-415415 W391.4 W37.42 V13.9 A21.39%
ELNSM54M-HC-LV-420420 W396.3 W37.52 V14 A21.65%
ELNSM54M-HC-LV-425425 W401.1 W37.62 V14.1 A21.91%
ELNSM54M-HC-LV-430430 W405.9 W37.72 V14.2 A22.16%
ELNSM54M-HC-LV-435435 W410.8 W37.82 V14.3 A22.42%

Engineering FAQ — Elin Energy (Sirius PV) ELNSM54M-HC-LV-390

How many Elin Energy (Sirius PV) ELNSM54M-HC-LV-390 panels can fit in one 600V string?
At -10°C (14°F) ambient, the ELNSM54M-HC-LV-390 open-circuit voltage rises from 36.92V to 39.94V (using βVoc -0.234%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Elin Energy (Sirius PV) ELNSM54M-HC-LV-390?
Rated at 390W STC, the ELNSM54M-HC-LV-390 carries a 367.3W PTC rating (94.2% PTC/STC ratio) and 20.1% module efficiency across 1.94 m² (20.9 sq ft).
Is the Elin Energy (Sirius PV) ELNSM54M-HC-LV-390 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More Elin Energy (Sirius PV) Solar Panels

ELNSM54M-HC-N-415 (415W)ELNSM54M-HC-BF-395 (395W)ELNSM54M-HC-390 (390W)ELNSM66M-HC-N-G-635 (635W)ELNSM66M-HC-N-G-605 (605W)ELNSM42M-HC-N-SNRN-420 (420W)All Elin Energy (Sirius PV) Equipment →