FreeVolt ECP-PVGRAF-HC-BF580-144MT-W
580 W, 144 half-cut cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
580W / 551.6W
Efficiency
22.48%
Voc / Vmp
53.3V / 46.5V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | FreeVolt |
|---|---|
| Model Number (MPN) | ECP-PVGRAF-HC-BF580-144MT-W |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 580 W |
| Real-World Output (PTC) | 551.6 W (95.1% of STC) |
| Module Efficiency | 22.48% (224.8 W/m²) |
| Open-Circuit Voltage (Voc) | 53.3 V |
| Maximum Power Voltage (Vmp) | 46.5 V |
| Short-Circuit Current (Isc) | 13.16 A (NEC 1.25× = 16.45 A) |
| Maximum Power Current (Imp) | 12.48 A |
| Temp. Coeff. Power (γPmax) | -0.292 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.257 %/°C |
| Temp. Coeff. Current (αIsc) | +0.042 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.58 m² (27.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.257%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.3 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 56.72 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 58.09 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 59.46 V | 10 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 60.83 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.38 kW | 305 sq ft (28.4 m²) |
| 8 kW | 14 panels | 8.12 kW | 389 sq ft (36.1 m²) |
| 10 kW | 18 panels | 10.44 kW | 500 sq ft (46.4 m²) |
| 12 kW | 21 panels | 12.18 kW | 583 sq ft (54.2 m²) |
Compatible CEC-Listed Inverters for ECP-PVGRAF-HC-BF580-144MT-W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.51 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This FreeVolt Series (9 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| ECP-PVGRAF-HC-BF550-144MT-W | 550 W | 522.5 W | 52.5 V | 12.68 A | 21.32% |
| ECP-PVGRAF-HC-BF555-144MT-W | 555 W | 527.3 W | 52.6 V | 12.76 A | 21.51% |
| ECP-PVGRAF-HC-BF560-144MT-W | 560 W | 532.2 W | 52.7 V | 12.84 A | 21.71% |
| ECP-PVGRAF-HC-BF565-144MT-W | 565 W | 537 W | 52.9 V | 12.92 A | 21.9% |
| ECP-PVGRAF-HC-BF570-144MT-W | 570 W | 541.9 W | 53 V | 13 A | 22.09% |
| ECP-PVGRAF-HC-BF575-144MT-W | 575 W | 546.8 W | 53.2 V | 13.08 A | 22.29% |
| ECP-PVGRAF-HC-BF585-144MT-W | 585 W | 556.5 W | 53.4 V | 13.24 A | 22.67% |
| ECP-PVGRAF-HC-BF590-144MT-W | 590 W | 561.3 W | 53.6 V | 13.32 A | 22.87% |
Engineering FAQ — FreeVolt ECP-PVGRAF-HC-BF580-144MT-W
How many FreeVolt ECP-PVGRAF-HC-BF580-144MT-W panels can fit in one 600V string?
At -10°C (14°F) ambient, the ECP-PVGRAF-HC-BF580-144MT-W open-circuit voltage rises from 53.3V to 58.09V (using βVoc -0.257%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the FreeVolt ECP-PVGRAF-HC-BF580-144MT-W?
Rated at 580W STC, the ECP-PVGRAF-HC-BF580-144MT-W carries a 551.6W PTC rating (95.1% PTC/STC ratio) and 22.48% module efficiency across 2.58 m² (27.8 sq ft).
Is the FreeVolt ECP-PVGRAF-HC-BF580-144MT-W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.