605 W, 156 cell double glass monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
605W / 570.9W
Efficiency
21.84%
Voc / Vmp
54.29V / 45.67V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | G-Star |
|---|---|
| Model Number (MPN) | GSD7G78M-605WT |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 605 W |
| Real-World Output (PTC) | 570.9 W (94.4% of STC) |
| Module Efficiency | 21.84% (218.4 W/m²) |
| Open-Circuit Voltage (Voc) | 54.29 V |
| Maximum Power Voltage (Vmp) | 45.67 V |
| Short-Circuit Current (Isc) | 14.14 A (NEC 1.25× = 17.68 A) |
| Maximum Power Current (Imp) | 13.25 A |
| Temp. Coeff. Power (γPmax) | -0.332 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.296 %/°C |
| Temp. Coeff. Current (αIsc) | +0.044 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.77 m² (29.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.296%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 54.29 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 58.31 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 59.91 V | 10 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 61.52 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 63.13 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.05 kW | 298 sq ft (27.7 m²) |
| 8 kW | 14 panels | 8.47 kW | 417 sq ft (38.8 m²) |
| 10 kW | 17 panels | 10.29 kW | 507 sq ft (47.1 m²) |
| 12 kW | 20 panels | 12.10 kW | 596 sq ft (55.4 m²) |
Compatible CEC-Listed Inverters for GSD7G78M-605WT
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This G-Star Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GSD7G78M-575WT | 575 W | 541.9 W | 53.54 V | 13.72 A | 20.76% |
| GSD7G78M-580WT | 580 W | 546.8 W | 53.59 V | 13.79 A | 20.94% |
| GSD7G78M-585WT | 585 W | 551.6 W | 53.73 V | 13.86 A | 21.12% |
| GSD7G78M-590WT | 590 W | 556.4 W | 53.87 V | 13.93 A | 21.3% |
| GSD7G78M-595WT | 595 W | 561.2 W | 54.01 V | 14 A | 21.48% |
| GSD7G78M-600WT | 600 W | 566.1 W | 54.15 V | 14.07 A | 21.66% |
| GSD7G78M-610WT | 610 W | 575.8 W | 54.43 V | 14.21 A | 22.02% |
Engineering FAQ — G-Star GSD7G78M-605WT
How many G-Star GSD7G78M-605WT panels can fit in one 600V string?
At -10°C (14°F) ambient, the GSD7G78M-605WT open-circuit voltage rises from 54.29V to 59.91V (using βVoc -0.296%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the G-Star GSD7G78M-605WT?
Rated at 605W STC, the GSD7G78M-605WT carries a 570.9W PTC rating (94.4% PTC/STC ratio) and 21.84% module efficiency across 2.77 m² (29.8 sq ft).
Is the G-Star GSD7G78M-605WT listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.