G-Star GSD8R48T-470WT
470 W, 96 half-cut cell double glass monocrystalline module, white mesh, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
470W / 447.6W
Efficiency
23.74%
Voc / Vmp
36.41V / 30.87V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | G-Star |
|---|---|
| Model Number (MPN) | GSD8R48T-470WT |
| Cell Technology | Mono-c-Si · 96 cells |
| Nameplate Power (Pmax STC) | 470 W |
| Real-World Output (PTC) | 447.6 W (95.2% of STC) |
| Module Efficiency | 23.74% (237.4 W/m²) |
| Open-Circuit Voltage (Voc) | 36.41 V |
| Maximum Power Voltage (Vmp) | 30.87 V |
| Short-Circuit Current (Isc) | 16.03 A (NEC 1.25× = 20.04 A) |
| Maximum Power Current (Imp) | 15.23 A |
| Temp. Coeff. Power (γPmax) | -0.293 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.236 %/°C |
| Temp. Coeff. Current (αIsc) | +0.042 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.98 m² (21.3 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.236%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 36.41 V | 16 | 27 |
| 0°C / 32°F Freezing / Mild Winter | 38.56 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 39.42 V | 15 | 25 |
| -20°C / -4°F Northeast / Midwest Winter | 40.28 V | 14 | 24 |
| -30°C / -22°F Northern Plains / Mountain | 41.14 V | 14 | 24 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.11 kW | 277 sq ft (25.7 m²) |
| 8 kW | 18 panels | 8.46 kW | 384 sq ft (35.6 m²) |
| 10 kW | 22 panels | 10.34 kW | 469 sq ft (43.6 m²) |
| 12 kW | 26 panels | 12.22 kW | 554 sq ft (51.5 m²) |
Compatible CEC-Listed Inverters for GSD8R48T-470WT
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–15 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.49 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This G-Star Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GSD8R48T-440WT | 440 W | 418.4 W | 35.15 V | 15.73 A | 22.22% |
| GSD8R48T-445WT | 445 W | 423.3 W | 35.36 V | 15.78 A | 22.47% |
| GSD8R48T-450WT | 450 W | 428.2 W | 35.57 V | 15.83 A | 22.73% |
| GSD8R48T-455WT | 455 W | 433 W | 35.78 V | 15.88 A | 22.98% |
| GSD8R48T-460WT | 460 W | 437.9 W | 35.99 V | 15.93 A | 23.23% |
| GSD8R48T-465WT | 465 W | 442.8 W | 36.2 V | 15.98 A | 23.48% |
Engineering FAQ — G-Star GSD8R48T-470WT
How many G-Star GSD8R48T-470WT panels can fit in one 600V string?
At -10°C (14°F) ambient, the GSD8R48T-470WT open-circuit voltage rises from 36.41V to 39.42V (using βVoc -0.236%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the G-Star GSD8R48T-470WT?
Rated at 470W STC, the GSD8R48T-470WT carries a 447.6W PTC rating (95.2% PTC/STC ratio) and 23.74% module efficiency across 1.98 m² (21.3 sq ft).
Is the G-Star GSD8R48T-470WT listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.