G-Star GSP7F54M(H)390BB
390 W, 108 cell monocrystalline module, black backsheet, black frame, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
390W / 367W
Efficiency
20%
Voc / Vmp
36.5V / 30.65V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | G-Star |
|---|---|
| Model Number (MPN) | GSP7F54M(H)390BB |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 390 W |
| Real-World Output (PTC) | 367 W (94.1% of STC) |
| Module Efficiency | 20% (200 W/m²) |
| Open-Circuit Voltage (Voc) | 36.5 V |
| Maximum Power Voltage (Vmp) | 30.65 V |
| Short-Circuit Current (Isc) | 13.61 A (NEC 1.25× = 17.01 A) |
| Maximum Power Current (Imp) | 12.73 A |
| Temp. Coeff. Power (γPmax) | -0.333 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.263 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.263%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 36.5 V | 16 | 27 |
| 0°C / 32°F Freezing / Mild Winter | 38.9 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 39.86 V | 15 | 25 |
| -20°C / -4°F Northeast / Midwest Winter | 40.82 V | 14 | 24 |
| -30°C / -22°F Northern Plains / Mountain | 41.78 V | 14 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.24 kW | 336 sq ft (31.2 m²) |
| 8 kW | 21 panels | 8.19 kW | 441 sq ft (40.9 m²) |
| 10 kW | 26 panels | 10.14 kW | 546 sq ft (50.7 m²) |
| 12 kW | 31 panels | 12.09 kW | 651 sq ft (60.4 m²) |
Compatible CEC-Listed Inverters for GSP7F54M(H)390BB
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–15 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.44 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–20 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This G-Star Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GSP7F54M(H)395BB | 395 W | 371.8 W | 36.75 V | 13.69 A | 20.26% |
| GSP7F54M(H)400BB | 400 W | 376.6 W | 37 V | 13.78 A | 20.51% |
| GSP7F54M(H)405BB | 405 W | 381.4 W | 37.25 V | 13.86 A | 20.77% |
| GSP7F54M(H)410BB | 410 W | 386.2 W | 37.5 V | 13.94 A | 21.03% |
| GSP7F54M(H)415BB | 415 W | 391.1 W | 37.75 V | 14.02 A | 21.28% |
Engineering FAQ — G-Star GSP7F54M(H)390BB
How many G-Star GSP7F54M(H)390BB panels can fit in one 600V string?
At -10°C (14°F) ambient, the GSP7F54M(H)390BB open-circuit voltage rises from 36.5V to 39.86V (using βVoc -0.263%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the G-Star GSP7F54M(H)390BB?
Rated at 390W STC, the GSP7F54M(H)390BB carries a 367W PTC rating (94.1% PTC/STC ratio) and 20% module efficiency across 1.95 m² (21.0 sq ft).
Is the G-Star GSP7F54M(H)390BB listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.