GAF RIAC 1000 (150W)
150 W DC, Thin Film CIGS ACPV Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
150W / 139.2W
Efficiency
13.81%
Voc / Vmp
62.5V / 48.1V
Max String (600V)
8 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | GAF |
|---|---|
| Model Number (MPN) | RIAC 1000 |
| Cell Technology | Thin Film · 100 cells |
| Nameplate Power (Pmax STC) | 150 W |
| Real-World Output (PTC) | 139.2 W (92.8% of STC) |
| Module Efficiency | 13.81% (138.1 W/m²) |
| Open-Circuit Voltage (Voc) | 62.5 V |
| Maximum Power Voltage (Vmp) | 48.1 V |
| Short-Circuit Current (Isc) | 3.45 A (NEC 1.25× = 4.31 A) |
| Maximum Power Current (Imp) | 3.12 A |
| Temp. Coeff. Power (γPmax) | -0.306 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.286 %/°C |
| Temp. Coeff. Current (αIsc) | +0.007 %/°C |
| Nominal Cell Temp (NOCT) | 47 °C |
| Dimensions (L × W) | 1656 × 656 mm (65.2" × 25.8") |
| Surface Area | 1.086 m² (11.7 sq ft) |
| Safety Listing | UL 1741 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.286%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 62.5 V | 9 | 16 |
| 0°C / 32°F Freezing / Mild Winter | 66.97 V | 8 | 14 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 68.76 V | 8 | 14 |
| -20°C / -4°F Northeast / Midwest Winter | 70.54 V | 8 | 14 |
| -30°C / -22°F Northern Plains / Mountain | 72.33 V | 8 | 13 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 40 panels | 6.00 kW | 468 sq ft (43.4 m²) |
| 8 kW | 54 panels | 8.10 kW | 631 sq ft (58.6 m²) |
| 10 kW | 67 panels | 10.05 kW | 783 sq ft (72.8 m²) |
| 12 kW | 80 panels | 12.00 kW | 935 sq ft (86.9 m²) |
CEC-Listed US Equivalents to GAF RIAC 1000
Looking to build a compliant US residential system with comparable wattage (150W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for RIAC 1000
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–8 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–11 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 4–7 panels/string at -10°C | Verify Pair |
| Growatt SPH 3000TL BL-US | Hybrid | 2.934 kW | 93.5% | 4–6 panels/string at -10°C | Verify Pair |
| Growatt MIN 3000TL-XH-US | Hybrid | 3.095 kW | 97% | 4–6 panels/string at -10°C | Verify Pair |
Engineering FAQ — GAF RIAC 1000
How many GAF RIAC 1000 panels can fit in one 600V string?
At -10°C (14°F) ambient, the RIAC 1000 open-circuit voltage rises from 62.5V to 68.76V (using βVoc -0.286%/°C), allowing up to 8 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the GAF RIAC 1000?
Rated at 150W STC, the RIAC 1000 carries a 139.2W PTC rating (92.8% PTC/STC ratio) and 13.81% module efficiency across 1.086 m² (11.7 sq ft).
Is the GAF RIAC 1000 listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1741). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.