GA Legacy / Replacement ReferenceUL 1741

GAF RIAC 1000 (150W)

150 W DC, Thin Film CIGS ACPV Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
150W / 139.2W
Efficiency
13.81%
Voc / Vmp
62.5V / 48.1V
Max String (600V)
8 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
GAF RIAC 1000 — Illustrative category photo — not this exact model · Real thin-film CdTe photovoltaic solar array
Illustrative category photo — not this exact model · Real thin-film CdTe photovoltaic solar arrayWikimedia Commons — File:NREL Array.jpg (Public domain)
MODULE FOOTPRINT (100 CELLS) 1656mm (65.2") 656mm (25.8") STC I–V CURVE & COLD VOC (−10°C) −10°C 68.76V Isc 3.45A MPP 150W (48.1V · 3.12A) Voc 62.5V DC Voltage (V) · Efficiency 13.81%

Electrical & Thermal Specifications (STC)

GAF RIAC 1000 Electrical and Mechanical Specifications
ManufacturerGAF
Model Number (MPN)RIAC 1000
Cell TechnologyThin Film · 100 cells
Nameplate Power (Pmax STC)150 W
Real-World Output (PTC)139.2 W (92.8% of STC)
Module Efficiency13.81% (138.1 W/m²)
Open-Circuit Voltage (Voc)62.5 V
Maximum Power Voltage (Vmp)48.1 V
Short-Circuit Current (Isc)3.45 A (NEC 1.25× = 4.31 A)
Maximum Power Current (Imp)3.12 A
Temp. Coeff. Power (γPmax)-0.306 %/°C
Temp. Coeff. Voltage (βVoc)-0.286 %/°C
Temp. Coeff. Current (αIsc)+0.007 %/°C
Nominal Cell Temp (NOCT)47 °C
Dimensions (L × W)1656 × 656 mm (65.2" × 25.8")
Surface Area1.086 m² (11.7 sq ft)
Safety ListingUL 1741

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.286%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for RIAC 1000
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
62.5 V916
0°C / 32°F
Freezing / Mild Winter
66.97 V814
-10°C / 14°F
TX / Southeast / Mid-Atlantic
68.76 V814
-20°C / -4°F
Northeast / Midwest Winter
70.54 V814
-30°C / -22°F
Northern Plains / Mountain
72.33 V813

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using RIAC 1000
Target SizePanels NeededActual DCRoof Footprint
6 kW40 panels6.00 kW468 sq ft (43.4 m²)
8 kW54 panels8.10 kW631 sq ft (58.6 m²)
10 kW67 panels10.05 kW783 sq ft (72.8 m²)
12 kW80 panels12.00 kW935 sq ft (86.9 m²)

CEC-Listed US Equivalents to GAF RIAC 1000

Looking to build a compliant US residential system with comparable wattage (150W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:

CEC-Listed · Residential320 W
REC Solar · UL 61730

REC320TP2M

Efficiency: 19.79%
Datasheet →
CEC-Listed · Residential320 W
Solar4America Technology · UL 61730

OPAL320-60MH5

Efficiency: 19.75%
Datasheet →
CEC-Listed · Residential325 W
GermanSolar USA · UL 61730

GSM10-Agri-325W-AG

Efficiency: 22.11%
Datasheet →

Compatible CEC-Listed Inverters for RIAC 1000

Open full string calculator with this panel →
Compatible US-Certified Inverters for GAF RIAC 1000
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–8 panels/string at -10°CVerify Pair
Fronius Primo 3.8-1 208-240String3.8 kW95.5%3–11 panels/string at -10°CVerify Pair
GoodWe GEP5.0-1-US30String4.968 kW96.5%4–7 panels/string at -10°CVerify Pair
Growatt SPH 3000TL BL-USHybrid2.934 kW93.5%4–6 panels/string at -10°CVerify Pair
Growatt MIN 3000TL-XH-USHybrid3.095 kW97%4–6 panels/string at -10°CVerify Pair

Engineering FAQ — GAF RIAC 1000

How many GAF RIAC 1000 panels can fit in one 600V string?
At -10°C (14°F) ambient, the RIAC 1000 open-circuit voltage rises from 62.5V to 68.76V (using βVoc -0.286%/°C), allowing up to 8 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the GAF RIAC 1000?
Rated at 150W STC, the RIAC 1000 carries a 139.2W PTC rating (92.8% PTC/STC ratio) and 13.81% module efficiency across 1.086 m² (11.7 sq ft).
Is the GAF RIAC 1000 listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1741). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.