HT CEC-Listed · ResidentialUL 61730

Hansol Technics HA440AA-NNEA0

440 W, 108 half-cut cell double glass monocrystalline module, 1500 max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
440W / 417.5W
Efficiency
22.68%
Voc / Vmp
38.8V / 32.3V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Hansol Technics HA440AA-NNEA0 — Illustrative category photo — not this exact model · Real monocrystalline rooftop solar array
Illustrative category photo — not this exact model · Real monocrystalline rooftop solar arrayWikimedia Commons — File:Polycrystalline solar panel mj1.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (108 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 42.03V Isc 14.39A MPP 440W (32.3V · 13.63A) Voc 38.8V DC Voltage (V) · Efficiency 22.68%

Electrical & Thermal Specifications (STC)

Hansol Technics HA440AA-NNEA0 Electrical and Mechanical Specifications
ManufacturerHansol Technics
Model Number (MPN)HA440AA-NNEA0
Cell TechnologyMono-c-Si · 108 cells
Nameplate Power (Pmax STC)440 W
Real-World Output (PTC)417.5 W (94.9% of STC)
Module Efficiency22.68% (226.8 W/m²)
Open-Circuit Voltage (Voc)38.8 V
Maximum Power Voltage (Vmp)32.3 V
Short-Circuit Current (Isc)14.39 A (NEC 1.25× = 17.99 A)
Maximum Power Current (Imp)13.63 A
Temp. Coeff. Power (γPmax)-0.298 %/°C
Temp. Coeff. Voltage (βVoc)-0.238 %/°C
Temp. Coeff. Current (αIsc)+0.035 %/°C
Nominal Cell Temp (NOCT)43.7 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")
Surface Area1.94 m² (20.9 sq ft)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.238%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for HA440AA-NNEA0
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
38.8 V1525
0°C / 32°F
Freezing / Mild Winter
41.11 V1424
-10°C / 14°F
TX / Southeast / Mid-Atlantic
42.03 V1423
-20°C / -4°F
Northeast / Midwest Winter
42.96 V1323
-30°C / -22°F
Northern Plains / Mountain
43.88 V1322

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using HA440AA-NNEA0
Target SizePanels NeededActual DCRoof Footprint
6 kW14 panels6.16 kW292 sq ft (27.2 m²)
8 kW19 panels8.36 kW397 sq ft (36.9 m²)
10 kW23 panels10.12 kW480 sq ft (44.6 m²)
12 kW28 panels12.32 kW585 sq ft (54.3 m²)

Compatible CEC-Listed Inverters for HA440AA-NNEA0

Open full string calculator with this panel →
Compatible US-Certified Inverters for Hansol Technics HA440AA-NNEA0
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–14 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%8–11 panels/string at -10°CVerify Pair
Enphase Energy IQ7PLUS-72-2-USMicroinverter0.29 kW97%1:1 micro pairing (1.52 DC/AC ratio)Verify Pair
Fronius Primo 5.0-1 208-240String5 kW96.5%4–19 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%4–11 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%4–11 panels/string at -10°CVerify Pair

Other Power Classes in This Hansol Technics Series (5 total CEC variants)

Sibling Power Classes in the Hansol Technics Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
HA420AA-NNEA0420 W398.1 W38 V14.11 A21.65%
HA425AA-NNEA0425 W402.9 W38.2 V14.18 A21.91%
HA430AA-NNEA0430 W407.8 W38.4 V14.25 A22.16%
HA435AA-NNEA0435 W412.6 W38.6 V14.32 A22.42%

Engineering FAQ — Hansol Technics HA440AA-NNEA0

How many Hansol Technics HA440AA-NNEA0 panels can fit in one 600V string?
At -10°C (14°F) ambient, the HA440AA-NNEA0 open-circuit voltage rises from 38.8V to 42.03V (using βVoc -0.238%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hansol Technics HA440AA-NNEA0?
Rated at 440W STC, the HA440AA-NNEA0 carries a 417.5W PTC rating (94.9% PTC/STC ratio) and 22.68% module efficiency across 1.94 m² (20.9 sq ft).
Is the Hansol Technics HA440AA-NNEA0 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More Hansol Technics Solar Panels

HA550XD-GNEA0 (550W)HA530XD-GNEA0 (530W)HA525XD-GLEA0 (525W)HA420AA-NNEA0 (420W)HS 405 XA-CLEA0 (405W)HS 395 XA-CLEA0 (395W)All Hansol Technics Equipment →