Hyundai Energy HiS-T425NF(BK)
425W, 108 half-cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
425W / 401.9W
Efficiency
21.91%
Voc / Vmp
39.29V / 32.41V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hyundai Energy |
|---|---|
| Model Number (MPN) | HiS-T425NF(BK) |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 425 W |
| Real-World Output (PTC) | 401.9 W (94.6% of STC) |
| Module Efficiency | 21.91% (219.1 W/m²) |
| Open-Circuit Voltage (Voc) | 39.29 V |
| Maximum Power Voltage (Vmp) | 32.41 V |
| Short-Circuit Current (Isc) | 13.67 A (NEC 1.25× = 17.09 A) |
| Maximum Power Current (Imp) | 13.12 A |
| Temp. Coeff. Power (γPmax) | -0.277 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.222 %/°C |
| Temp. Coeff. Current (αIsc) | +0.033 %/°C |
| Nominal Cell Temp (NOCT) | 46 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.94 m² (20.9 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.222%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.29 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.47 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.34 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.22 V | 13 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 44.09 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.38 kW | 313 sq ft (29.1 m²) |
| 8 kW | 19 panels | 8.07 kW | 397 sq ft (36.9 m²) |
| 10 kW | 24 panels | 10.20 kW | 501 sq ft (46.6 m²) |
| 12 kW | 29 panels | 12.32 kW | 606 sq ft (56.3 m²) |
Compatible CEC-Listed Inverters for HiS-T425NF(BK)
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-72-2-US | Microinverter | 0.28 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hyundai Energy Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HiS-T430NF(BK) | 430 W | 406.8 W | 39.49 V | 13.83 A | 22.16% |
| HiS-T435NF(BK) | 435 W | 411.6 W | 39.69 V | 13.91 A | 22.42% |
| HiS-T440NF(BK) | 440 W | 416.5 W | 39.9 V | 14.06 A | 22.68% |
| HiS-T445NF(BK) | 445 W | 421.3 W | 40.1 V | 14.14 A | 22.94% |
Engineering FAQ — Hyundai Energy HiS-T425NF(BK)
How many Hyundai Energy HiS-T425NF(BK) panels can fit in one 600V string?
At -10°C (14°F) ambient, the HiS-T425NF(BK) open-circuit voltage rises from 39.29V to 42.34V (using βVoc -0.222%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hyundai Energy HiS-T425NF(BK)?
Rated at 425W STC, the HiS-T425NF(BK) carries a 401.9W PTC rating (94.6% PTC/STC ratio) and 21.91% module efficiency across 1.94 m² (20.9 sq ft).
Is the Hyundai Energy HiS-T425NF(BK) listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.