Illuminate USA IL5-72HBD-540M
540 W, 144 half-cut cell bifacial dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
540W / 497.4W
Efficiency
21.51%
Voc / Vmp
49.5V / 41.7V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Illuminate USA |
|---|---|
| Model Number (MPN) | IL5-72HBD-540M |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 540 W |
| Real-World Output (PTC) | 497.4 W (92.1% of STC) |
| Module Efficiency | 21.51% (215.1 W/m²) |
| Open-Circuit Voltage (Voc) | 49.5 V |
| Maximum Power Voltage (Vmp) | 41.7 V |
| Short-Circuit Current (Isc) | 13.85 A (NEC 1.25× = 17.31 A) |
| Maximum Power Current (Imp) | 12.97 A |
| Temp. Coeff. Power (γPmax) | -0.354 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.266 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 48.7 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.51 m² (27.0 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.266%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.5 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.79 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.11 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.43 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.74 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.48 kW | 324 sq ft (30.1 m²) |
| 8 kW | 15 panels | 8.10 kW | 405 sq ft (37.6 m²) |
| 10 kW | 19 panels | 10.26 kW | 513 sq ft (47.7 m²) |
| 12 kW | 23 panels | 12.42 kW | 621 sq ft (57.7 m²) |
Compatible CEC-Listed Inverters for IL5-72HBD-540M
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Illuminate USA Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| IL5-72HBD-545M | 545 W | 502.1 W | 49.7 V | 13.92 A | 21.71% |
| IL5-72HBD-550M | 550 W | 506.9 W | 49.8 V | 13.99 A | 21.91% |
| IL5-72HBD-555M | 555 W | 511.7 W | 50 V | 14.05 A | 22.11% |
| IL5-72HBD-560M | 560 W | 516.4 W | 50.1 V | 14.1 A | 22.31% |
| IL5-72HBD-565M | 565 W | 521.2 W | 50.3 V | 14.16 A | 22.51% |
Engineering FAQ — Illuminate USA IL5-72HBD-540M
How many Illuminate USA IL5-72HBD-540M panels can fit in one 600V string?
At -10°C (14°F) ambient, the IL5-72HBD-540M open-circuit voltage rises from 49.5V to 54.11V (using βVoc -0.266%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Illuminate USA IL5-72HBD-540M?
Rated at 540W STC, the IL5-72HBD-540M carries a 497.4W PTC rating (92.1% PTC/STC ratio) and 21.51% module efficiency across 2.51 m² (27.0 sq ft).
Is the Illuminate USA IL5-72HBD-540M listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.