INDEPWR Solar iPWR-M10-54BX2D-430W
430 W, 108 half-cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
430W / 408W
Efficiency
22.05%
Voc / Vmp
39.4V / 32.8V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | INDEPWR Solar |
|---|---|
| Model Number (MPN) | iPWR-M10-54BX2D-430W |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 430 W |
| Real-World Output (PTC) | 408 W (94.9% of STC) |
| Module Efficiency | 22.05% (220.5 W/m²) |
| Open-Circuit Voltage (Voc) | 39.4 V |
| Maximum Power Voltage (Vmp) | 32.8 V |
| Short-Circuit Current (Isc) | 13.88 A (NEC 1.25× = 17.35 A) |
| Maximum Power Current (Imp) | 13.1 A |
| Temp. Coeff. Power (γPmax) | -0.299 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.246 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.246%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.4 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.82 V | 14 | 23 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.79 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.76 V | 13 | 22 |
| -30°C / -22°F Northern Plains / Mountain | 44.73 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.02 kW | 294 sq ft (27.3 m²) |
| 8 kW | 19 panels | 8.17 kW | 399 sq ft (37.0 m²) |
| 10 kW | 24 panels | 10.32 kW | 504 sq ft (46.8 m²) |
| 12 kW | 28 panels | 12.04 kW | 588 sq ft (54.6 m²) |
Compatible CEC-Listed Inverters for iPWR-M10-54BX2D-430W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-72-2-US | Microinverter | 0.28 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This INDEPWR Solar Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| iPWR-M10-54BX2D-435W | 435 W | 412.9 W | 39.6 V | 13.95 A | 22.31% |
| iPWR-M10-54BX2D-440W | 440 W | 417.7 W | 39.8 V | 14.02 A | 22.56% |
| iPWR-M10-54BX2D-445W | 445 W | 422.6 W | 40 V | 14.09 A | 22.82% |
| iPWR-M10-54BX2D-450W | 450 W | 427.5 W | 40.2 V | 14.16 A | 23.08% |
Engineering FAQ — INDEPWR Solar iPWR-M10-54BX2D-430W
How many INDEPWR Solar iPWR-M10-54BX2D-430W panels can fit in one 600V string?
At -10°C (14°F) ambient, the iPWR-M10-54BX2D-430W open-circuit voltage rises from 39.4V to 42.79V (using βVoc -0.246%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the INDEPWR Solar iPWR-M10-54BX2D-430W?
Rated at 430W STC, the iPWR-M10-54BX2D-430W carries a 408W PTC rating (94.9% PTC/STC ratio) and 22.05% module efficiency across 1.95 m² (21.0 sq ft).
Is the INDEPWR Solar iPWR-M10-54BX2D-430W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.