JOLYWOOD (TAIZHOU) SOLAR JW-HD132N-R2-595
595 W, 132 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
595W / 564W
Efficiency
22.04%
Voc / Vmp
48.1V / 40V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | JOLYWOOD (TAIZHOU) SOLAR |
|---|---|
| Model Number (MPN) | JW-HD132N-R2-595 |
| Cell Technology | Mono-c-Si (Bifacial) · 132 cells |
| Nameplate Power (Pmax STC) | 595 W |
| Real-World Output (PTC) | 564 W (94.8% of STC) |
| Module Efficiency | 22.04% (220.4 W/m²) |
| Open-Circuit Voltage (Voc) | 48.1 V |
| Maximum Power Voltage (Vmp) | 40 V |
| Short-Circuit Current (Isc) | 15.76 A (NEC 1.25× = 19.70 A) |
| Maximum Power Current (Imp) | 14.89 A |
| Temp. Coeff. Power (γPmax) | -0.292 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.241 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 44.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.7 m² (29.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.241%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 48.1 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 51 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 52.16 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53.32 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.48 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.54 kW | 320 sq ft (29.7 m²) |
| 8 kW | 14 panels | 8.33 kW | 407 sq ft (37.8 m²) |
| 10 kW | 17 panels | 10.12 kW | 494 sq ft (45.9 m²) |
| 12 kW | 21 panels | 12.49 kW | 610 sq ft (56.7 m²) |
Compatible CEC-Listed Inverters for JW-HD132N-R2-595
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.55 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This JOLYWOOD (TAIZHOU) SOLAR Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| JW-HD132N-R2-610 | 610 W | 578.5 W | 49 V | 15.86 A | 22.59% |
| JW-HD132N-R2-615 | 615 W | 583.4 W | 49.3 V | 15.9 A | 22.78% |
| JW-HD132N-R2-620 | 620 W | 588.3 W | 49.6 V | 15.94 A | 22.96% |
Engineering FAQ — JOLYWOOD (TAIZHOU) SOLAR JW-HD132N-R2-595
How many JOLYWOOD (TAIZHOU) SOLAR JW-HD132N-R2-595 panels can fit in one 600V string?
At -10°C (14°F) ambient, the JW-HD132N-R2-595 open-circuit voltage rises from 48.1V to 52.16V (using βVoc -0.241%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the JOLYWOOD (TAIZHOU) SOLAR JW-HD132N-R2-595?
Rated at 595W STC, the JW-HD132N-R2-595 carries a 564W PTC rating (94.8% PTC/STC ratio) and 22.04% module efficiency across 2.7 m² (29.1 sq ft).
Is the JOLYWOOD (TAIZHOU) SOLAR JW-HD132N-R2-595 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.