JOLYWOOD (TAIZHOU) SOLAR JW-HD96N-R2-440
440 W, 96 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
440W / 417.1W
Efficiency
22%
Voc / Vmp
35.2V / 29.5V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | JOLYWOOD (TAIZHOU) SOLAR |
|---|---|
| Model Number (MPN) | JW-HD96N-R2-440 |
| Cell Technology | Mono-c-Si (Bifacial) · 96 cells |
| Nameplate Power (Pmax STC) | 440 W |
| Real-World Output (PTC) | 417.1 W (94.8% of STC) |
| Module Efficiency | 22% (220 W/m²) |
| Open-Circuit Voltage (Voc) | 35.2 V |
| Maximum Power Voltage (Vmp) | 29.5 V |
| Short-Circuit Current (Isc) | 15.8 A (NEC 1.25× = 19.75 A) |
| Maximum Power Current (Imp) | 14.91 A |
| Temp. Coeff. Power (γPmax) | -0.292 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.241 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 44.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2 m² (21.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.241%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 35.2 V | 17 | 28 |
| 0°C / 32°F Freezing / Mild Winter | 37.32 V | 16 | 26 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 38.17 V | 15 | 26 |
| -20°C / -4°F Northeast / Midwest Winter | 39.02 V | 15 | 25 |
| -30°C / -22°F Northern Plains / Mountain | 39.87 V | 15 | 25 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.16 kW | 301 sq ft (28.0 m²) |
| 8 kW | 19 panels | 8.36 kW | 409 sq ft (38.0 m²) |
| 10 kW | 23 panels | 10.12 kW | 495 sq ft (46.0 m²) |
| 12 kW | 28 panels | 12.32 kW | 603 sq ft (56.0 m²) |
Compatible CEC-Listed Inverters for JW-HD96N-R2-440
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–15 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This JOLYWOOD (TAIZHOU) SOLAR Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| JW-HD96N-R2-445 | 445 W | 421.9 W | 35.4 V | 15.83 A | 22.25% |
| JW-HD96N-R2-450 | 450 W | 426.8 W | 35.6 V | 15.86 A | 22.5% |
Engineering FAQ — JOLYWOOD (TAIZHOU) SOLAR JW-HD96N-R2-440
How many JOLYWOOD (TAIZHOU) SOLAR JW-HD96N-R2-440 panels can fit in one 600V string?
At -10°C (14°F) ambient, the JW-HD96N-R2-440 open-circuit voltage rises from 35.2V to 38.17V (using βVoc -0.241%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the JOLYWOOD (TAIZHOU) SOLAR JW-HD96N-R2-440?
Rated at 440W STC, the JW-HD96N-R2-440 carries a 417.1W PTC rating (94.8% PTC/STC ratio) and 22% module efficiency across 2 m² (21.5 sq ft).
Is the JOLYWOOD (TAIZHOU) SOLAR JW-HD96N-R2-440 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.