KE CEC-Listed · ResidentialUL 61730

KOSOL ENERGIE PVT KE470R

470 W, 96 cell double glass monocrystalline module, with white or black mesh, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
470W / 447.6W
Efficiency
23.74%
Voc / Vmp
36.4V / 30.9V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
KOSOL ENERGIE PVT KE470R — Illustrative category photo — not this exact model · Real monocrystalline rooftop solar array
Illustrative category photo — not this exact model · Real monocrystalline rooftop solar arrayWikimedia Commons — File:Polycrystalline solar panel mj1.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (108 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 39.42V Isc 16.03A MPP 470W (30.9V · 15.23A) Voc 36.4V DC Voltage (V) · Efficiency 23.74%

Electrical & Thermal Specifications (STC)

KOSOL ENERGIE PVT KE470R Electrical and Mechanical Specifications
ManufacturerKOSOL ENERGIE PVT
Model Number (MPN)KE470R
Cell TechnologyMono-c-Si · 108 cells
Nameplate Power (Pmax STC)470 W
Real-World Output (PTC)447.6 W (95.2% of STC)
Module Efficiency23.74% (237.4 W/m²)
Open-Circuit Voltage (Voc)36.4 V
Maximum Power Voltage (Vmp)30.9 V
Short-Circuit Current (Isc)16.03 A (NEC 1.25× = 20.04 A)
Maximum Power Current (Imp)15.23 A
Temp. Coeff. Power (γPmax)-0.293 %/°C
Temp. Coeff. Voltage (βVoc)-0.237 %/°C
Temp. Coeff. Current (αIsc)+0.042 %/°C
Nominal Cell Temp (NOCT)43.1 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")
Surface Area1.98 m² (21.3 sq ft)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.237%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for KE470R
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
36.4 V1627
0°C / 32°F
Freezing / Mild Winter
38.56 V1525
-10°C / 14°F
TX / Southeast / Mid-Atlantic
39.42 V1525
-20°C / -4°F
Northeast / Midwest Winter
40.28 V1424
-30°C / -22°F
Northern Plains / Mountain
41.14 V1424

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using KE470R
Target SizePanels NeededActual DCRoof Footprint
6 kW13 panels6.11 kW277 sq ft (25.7 m²)
8 kW18 panels8.46 kW384 sq ft (35.6 m²)
10 kW22 panels10.34 kW469 sq ft (43.6 m²)
12 kW26 panels12.22 kW554 sq ft (51.5 m²)

Compatible CEC-Listed Inverters for KE470R

Open full string calculator with this panel →
Compatible US-Certified Inverters for KOSOL ENERGIE PVT KE470R
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–15 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%8–12 panels/string at -10°CVerify Pair
Enphase Energy IQ7X-96-2-USMicroinverter0.315 kW97%1:1 micro pairing (1.49 DC/AC ratio)Verify Pair
Fronius Primo GEN24 6.0 208-240 Plus SCHybrid6.005 kW97%5–15 panels/string at -10°CVerify Pair
GoodWe GEC6.0-1U-US20Hybrid6.01 kW96%5–12 panels/string at -10°CVerify Pair
GoodWe GW6000-SBP-US20Hybrid6.01 kW96%5–12 panels/string at -10°CVerify Pair

Other Power Classes in This KOSOL ENERGIE PVT Series (17 total CEC variants)

Sibling Power Classes in the KOSOL ENERGIE PVT Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
KE440R440 W418.4 W35.2 V15.73 A22.22%
KE445R445 W423.3 W35.4 V15.78 A22.47%
KE450R450 W428.1 W35.6 V15.83 A22.73%
KE455R455 W433 W35.8 V15.88 A22.98%
KE460R460 W437.9 W36 V15.93 A23.23%
KE465R465 W442.7 W36.2 V15.98 A23.48%
KE605R605 W575.5 W48.3 V15.71 A22.57%
KE610R610 W580.4 W48.5 V15.75 A22.76%
KE615R615 W585.2 W48.8 V15.79 A22.95%
KE620R620 W590.1 W49 V15.83 A23.13%
KE625R625 W595 W49.2 V15.87 A23.32%
KE630R630 W599.8 W49.4 V15.91 A23.51%
KE635R635 W604.7 W49.6 V15.95 A23.69%
KE640R640 W609.6 W49.9 V15.99 A23.88%

Engineering FAQ — KOSOL ENERGIE PVT KE470R

How many KOSOL ENERGIE PVT KE470R panels can fit in one 600V string?
At -10°C (14°F) ambient, the KE470R open-circuit voltage rises from 36.4V to 39.42V (using βVoc -0.237%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the KOSOL ENERGIE PVT KE470R?
Rated at 470W STC, the KE470R carries a 447.6W PTC rating (95.2% PTC/STC ratio) and 23.74% module efficiency across 1.98 m² (21.3 sq ft).
Is the KOSOL ENERGIE PVT KE470R listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More KOSOL ENERGIE PVT Solar Panels

KE565N (565W)KE560T (560W)KE530T (530W)KE450N (450W)KE440R (440W)KE420N (420W)All KOSOL ENERGIE PVT Equipment →