Leapton Energy LP182*182-M-72-MH-535W
535 W, 144 cell monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
535W / 502W
Efficiency
20.9%
Voc / Vmp
49.2V / 41V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Leapton Energy |
|---|---|
| Model Number (MPN) | LP182*182-M-72-MH-535W |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 535 W |
| Real-World Output (PTC) | 502 W (93.8% of STC) |
| Module Efficiency | 20.9% (209 W/m²) |
| Open-Circuit Voltage (Voc) | 49.2 V |
| Maximum Power Voltage (Vmp) | 41 V |
| Short-Circuit Current (Isc) | 13.81 A (NEC 1.25× = 17.26 A) |
| Maximum Power Current (Imp) | 13.05 A |
| Temp. Coeff. Power (γPmax) | -0.32 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.253 %/°C |
| Temp. Coeff. Current (αIsc) | +0.052 %/°C |
| Nominal Cell Temp (NOCT) | 45.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.56 m² (27.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.253%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.2 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.31 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.56 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.8 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.05 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.42 kW | 331 sq ft (30.7 m²) |
| 8 kW | 15 panels | 8.03 kW | 413 sq ft (38.4 m²) |
| 10 kW | 19 panels | 10.16 kW | 524 sq ft (48.6 m²) |
| 12 kW | 23 panels | 12.30 kW | 634 sq ft (58.9 m²) |
Compatible CEC-Listed Inverters for LP182*182-M-72-MH-535W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.39 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Leapton Energy Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| LP182*182-M-72-MH-540W | 540 W | 506.8 W | 49.4 V | 13.87 A | 21.09% |
| LP182*182-M-72-MH-545W | 545 W | 511.7 W | 49.6 V | 13.93 A | 21.29% |
| LP182*182-M-72-MH-550W | 550 W | 516.5 W | 49.8 V | 13.99 A | 21.48% |
| LP182*182-M-72-MH-555W | 555 W | 521.3 W | 50 V | 14.05 A | 21.68% |
| LP182*182-M-72-MH-560W | 560 W | 526.1 W | 50.2 V | 14.11 A | 21.88% |
| LP182*182-M-72-MH-565W | 565 W | 530.9 W | 50.4 V | 14.17 A | 22.07% |
| LP182*182-M-72-MH-570W | 570 W | 535.8 W | 50.6 V | 14.23 A | 22.27% |
Engineering FAQ — Leapton Energy LP182*182-M-72-MH-535W
How many Leapton Energy LP182*182-M-72-MH-535W panels can fit in one 600V string?
At -10°C (14°F) ambient, the LP182*182-M-72-MH-535W open-circuit voltage rises from 49.2V to 53.56V (using βVoc -0.253%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Leapton Energy LP182*182-M-72-MH-535W?
Rated at 535W STC, the LP182*182-M-72-MH-535W carries a 502W PTC rating (93.8% PTC/STC ratio) and 20.9% module efficiency across 2.56 m² (27.6 sq ft).
Is the Leapton Energy LP182*182-M-72-MH-535W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.