Mate Solar MS390M-54HB
390 W, 108 half-cut cell monocrystalline module, black frame, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
390W / 362.3W
Efficiency
19.9%
Voc / Vmp
37V / 30.4V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Mate Solar |
|---|---|
| Model Number (MPN) | MS390M-54HB |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 390 W |
| Real-World Output (PTC) | 362.3 W (92.9% of STC) |
| Module Efficiency | 19.9% (199 W/m²) |
| Open-Circuit Voltage (Voc) | 37 V |
| Maximum Power Voltage (Vmp) | 30.4 V |
| Short-Circuit Current (Isc) | 13.6 A (NEC 1.25× = 17.00 A) |
| Maximum Power Current (Imp) | 12.85 A |
| Temp. Coeff. Power (γPmax) | -0.349 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.26 %/°C |
| Temp. Coeff. Current (αIsc) | +0.056 %/°C |
| Nominal Cell Temp (NOCT) | 46 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.96 m² (21.1 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.26%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37 V | 16 | 27 |
| 0°C / 32°F Freezing / Mild Winter | 39.41 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 40.37 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 41.33 V | 14 | 24 |
| -30°C / -22°F Northern Plains / Mountain | 42.29 V | 14 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.24 kW | 338 sq ft (31.4 m²) |
| 8 kW | 21 panels | 8.19 kW | 443 sq ft (41.2 m²) |
| 10 kW | 26 panels | 10.14 kW | 549 sq ft (51.0 m²) |
| 12 kW | 31 panels | 12.09 kW | 654 sq ft (60.8 m²) |
Compatible CEC-Listed Inverters for MS390M-54HB
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.44 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This Mate Solar Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| MS395M-54HB | 395 W | 367.1 W | 37 V | 13.67 A | 20.15% |
| MS400M-54HB | 400 W | 371.9 W | 37.1 V | 13.74 A | 20.41% |
| MS405M-54HB | 405 W | 376.7 W | 37.2 V | 13.81 A | 20.66% |
| MS410M-54HB | 410 W | 381.5 W | 37.3 V | 13.88 A | 20.92% |
| MS415M-54HB | 415 W | 386.2 W | 37.4 V | 13.95 A | 21.17% |
| MS420M-54HB | 420 W | 391 W | 37.4 V | 14.02 A | 21.43% |
| MS425M-54HB | 425 W | 395.8 W | 37.5 V | 14.09 A | 21.68% |
Engineering FAQ — Mate Solar MS390M-54HB
How many Mate Solar MS390M-54HB panels can fit in one 600V string?
At -10°C (14°F) ambient, the MS390M-54HB open-circuit voltage rises from 37V to 40.37V (using βVoc -0.26%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Mate Solar MS390M-54HB?
Rated at 390W STC, the MS390M-54HB carries a 362.3W PTC rating (92.9% PTC/STC ratio) and 19.9% module efficiency across 1.96 m² (21.1 sq ft).
Is the Mate Solar MS390M-54HB listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.